The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

9051–9075 of 27089

  • HighFDA (Devices)·Z-0026-2025·2024-10-16

    BD Synapsys Laboratory Software May Display Incorrect Antibiotic Susceptibility Results

    BD Synapsys Informatics Solution versions 4.20–5.30 contain a software error that may incorrectly display antibiotic susceptibility results, potentially leading to inadequate or prolonged antibiotic treatment.

    Product
    BD Synapsys Informatics Solution with software versions: 4.20, 4.30, 5.10, 5.20 and 5.30- IVD standalone laboratory software solution providing data management and workflow management functionality across locations where clinical diagnostic activities take place. Catalog Number
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0038-2025·2024-10-16

    3M Tegaderm CHG I.V. Dressing Recalled for Foreign Contamination

    3M is recalling Tegaderm CHG I.V. Securement Dressing (REF 1658R) due to contamination with foreign substance matter. The affected lot (33WWRRR) was distributed to South Korea.

    Product
    3M Tegaderm CHG, Chlorhexidine Gluconate I.V. Securement Dressing, REF 1658R
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0052-2025·2024-10-16

    Monarch Platform Urology Device Recalled for Power Cord Electrical Hazard

    Auris Health is recalling Monarch Platform (Urology) devices due to strain relief defects in power cords that may cause electrical short and potential shock to operating room staff.

    Product
    Monarch Platform (Urology), REF: MON-000007, MON-000007-RFB
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0045-2025·2024-10-16

    Check-Flo Performer Introducer Set white caps may disconnect

    Cook Incorporated is recalling Check-Flo Performer Introducer Sets due to white caps that may disconnect from the shaft-hub connection. Affected units were distributed to Australia.

    Product
    Check-Flo Performer Introducer Set, Reference Part Number RCF-5.0-35-45-J, Order Number G27242. Performer Introducers are designed to perform as a guiding sheath and/or introducer sheath and come with a Check Flo valve.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0020-2025·2024-10-16

    Philips IntelliVue Patient Monitor Software Configuration Disables Enhanced ECG Alarms

    Philips patient monitors with Option CP2 software version P.01.01 were factory-configured incorrectly, leaving enhanced arrhythmia detection alarms disabled. Affected devices will not trigger yellow alarms for enhanced arrhythmia detection.

    Product
    IntelliVue Patient Monitor MX400/MX450/MX500/MX550 with software version P.01.01 and ordered with Option CP2 are affected as follows: 1) IntelliVue MX400 866060; 2) IntelliVue MX450 866062; 3) IntelliVue MX500 866064; 4) IntelliVue MX550 866066 Indica
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0039-2025·2024-10-16

    GE Healthcare Centricity Universal Viewer may fail to display latest diagnostic report

    GE Healthcare Centricity Universal Viewer Zero Footprint Client version 6.0 SP11.x may fail to show the latest diagnostic report by default when a study contains multiple DICOM structured reports in different series.

    Product
    GE Healthcare Centricity Universal Viewer Zero Footprint Client, Model/Catalog/Code Numbers: a)¿¿¿¿¿ 2089507-120; b)¿¿¿¿ 2089507-129; c)¿¿¿¿¿ 2089507-131; d)¿¿¿¿ 2089507-135; e)¿¿¿¿ 2089507-136; f)¿¿¿¿¿¿ 2089507-140; g)¿¿¿¿¿ 2089507-144; h)¿¿¿¿ 2089507-145; i)¿
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0023-2025·2024-10-16

    Knee Replacement Implant Recalled for Out-of-Spec Locking Tabs

    The FDA is recalling the Triathlon Universal TS Baseplate Size 2 knee implant due to defective locking tabs that may not properly engage with the tibial insert, potentially causing implant failure.

    Product
    Triathlon Universal TS Baseplate Size 2 - A single use sterile implantable device intended for cemented applications during primary and revision Total Knee Arthroplasty (TKA) when the Triathlon Knee System is selected for use. Catalog Number: 5521-B-200
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0025-2025·2024-10-16

    Medical Analyzer Software Flaw Allows Use of Expired Calibrator

    Beckman Coulter DxI 9000 immunoassay analyzers with software version 1.16.2 and prior can process orders using expired calibration material, potentially producing incorrect patient laboratory test results.

    Product
    Beckman Coulter Dxl 9000 Access Immunoassay Analyzer, REF #C11137. An in vitro diagnostic device used for the quantitative, semi-quantitative, or qualitative determination of various analyte concentrations found in human body fluids.
    Category
    Medical Device
    Distribution
    9 states
  • HighFDA (Devices)·Z-0053-2025·2024-10-16

    Medline Sterile Laparoscopy Pack Recalled for Component Defect

    Medline recalls Sterile Laparoscopy Packs due to a manufacturing defect in the Detachable Endo Pocket component. The tube may stretch from the pouch during surgical procedures, potentially affecting tissue collection.

    Product
    Medline Sterile Laparoscopy Pack, DYNJ68187A (REF), containing the component ConMed/Unimax Detachable Endo Pocket
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0037-2025·2024-10-16

    FDA Recalls EPIONE Device Due to Internal Component Corrosion

    Quantum Surgical recalls 2 units of the EPIONE device v1.0.2 because rust has developed on the central axis component of the Needle Guide product. These units were distributed in Florida.

    Product
    The EPIONE device v1.0.2 is a user controlled, stereotactic accessory device intended to assist in the planning and manual advancement of one or more instruments, as well as in verification of instrument position during Computed Tomography (CT) guided percutaneous procedures. Du
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0043-2025·2024-10-16

    Medical Device Recall: Respiratory Panel May Report Incorrect hMPV Results

    The NxTAG Respiratory Pathogen Panel may produce false positive results for human Metapneumovirus (hMPV), potentially leading to incorrect co-infection diagnoses.

    Product
    NxTAG Respiratory Pathogen Panel +SARS-CoV-2, REF: I056C0468
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0027-2025·2024-10-16

    Tonsil tray kits recalled for containing component under improper use recall

    Windstone Medical Packaging recalls 642 kits of Aligned Medical Tonsil Trays because they contain Cardinal Health Salem Sump PVC tubes that are subject to a separate recall for improper use.

    Product
    Aligned Medical Tonsil Tray REF AMS9300A that contains the Cardinal Health Salem Sump PVC tubes. Product packaged in a convenient manner for use in a general clinical procedure.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0042-2025·2024-10-16

    Respiratory Pathogen Panel Recalled Due to False Positive Results

    The NxTAG Respiratory Pathogen Panel is recalled due to false positive results for human metapneumovirus in about 7.6% of samples, especially those positive for other respiratory pathogens.

    Product
    NxTAG Respiratory Pathogen Panel, REF: I051C0447
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0050-2025·2024-10-16

    StealthStation S8 Spine Surgery Navigation System Recalled for Software Defects

    Medtronic is recalling 1,801 StealthStation S8 surgical navigation systems due to software anomalies that can flip navigation images during spine surgery and prevent warning messages for suboptimal imaging settings.

    Product
    StealthStation S8 App versions 1.3.0 and 1.3.2, (Model # 9735762) The StealthStation System, with StealthStation Spine software, is intended as an aid for precisely locating anatomical structures in either open or percutaneous neurosurgical and orthopedic procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0035-2025·2024-10-16

    Philips Patient Information Center iX Network Connectivity Issue Affects Settings Synchronization

    Philips Patient Information Center iX devices may fail to synchronize settings when network DHCP leases expire during offline operation, causing the devices to receive new IP addresses that are not recognized after reconnection.

    Product
    Patient Information Center iX, Product Code 866386, and Patient Information Center iX Expand, Product Code 866390, Software Revision 4.0.1
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0055-2025·2024-10-16

    Enterprise Imaging XERO Viewer medical software reference line placement error

    Enterprise Imaging XERO Viewer incorrectly displays reference lines on medical images due to a software defect affecting images with non-square pixel spacing. The misplaced reference lines may lead to diagnostic errors.

    Product
    Enterprise Imaging XERO Viewer- software application used for reference and diagnostic viewing of multispecialty medical imaging and non-imaging data . Enterprise Imaging XERO Viewer 8.0.0, 8.0.1, 8.1, 8.1.1, 8.1.2, 8.1.3,8.1.4, 8.2.0.000, 8.2.1.000, 8.2.2.000, 8.3.0.000, 8.3.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0021-2025·2024-10-16

    Trevo Trak 21 Microcatheter Distributed with Incorrect Instructions and Labels

    Stryker Neurovascular is recalling Trevo Trak 21 Microcatheters because Out-of-US approved instructions and labels were distributed instead of US-approved versions. Affected customers in CA and VA should contact the manufacturer.

    Product
    The Trevo Trak 21 Microcatheter is a single-lumen, braided shaft, variable stiffness catheter with radiopaque marker(s) on the distal end and a luer hub on the proximal end. The catheter shaft has a hydrophilic coating on the distal 100cm to reduce friction during use. The radiop
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0025-2025·2024-10-16

    Coca-Cola recalls Minute Maid Zero Sugar Lemonade due to mislabeling

    COCA COLA Consolidated LLC recalls Minute Maid Zero Sugar Lemonade cartons sold in Indiana, Kentucky, and Ohio. Regular Minute Maid Lemonade cans were incorrectly placed in Zero Sugar packaging.

    Product
    Minute Maid Zero Sugar Lemonade 12 cans carton UPC 0 25000 12115 9 CANNED UNDER THE AUTHORITY OF THE COCA-COLA COMPANY, ATLANTA, GA
    Category
    Food
    Distribution
    3 states
  • HighFDA (Devices)·Z-0054-2025·2024-10-16

    MEDIHONEY Dressing Applicator Pouch Recalled for Sterility Concerns

    Integra LifeSciences recalls MEDIHONEY Dressing applicator pouches due to potential pinholes that may compromise sterility. The recall affects approximately 120,124 units distributed across 36 US states and internationally.

    Product
    MEDIHONEY Dressing with Active Leptospermum Honey Wound and Burn Dressing W/APPLICATOR, 1.5oz tube (Model Number 31515) and 3.5oz tube (Model Number 31535)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0022-2025·2024-10-16

    FastPack TSH Calibrator Kit Recalled Due to Incorrect Barcode

    Qualigen Inc is recalling the FastPack TSH Calibrator Kit due to an incorrect barcode linked to incorrect information. The barcode defect may allow successful system calibration, but TSH test results obtained could be higher than expected.

    Product
    FastPack TSH Calibrator Kit, REF: 25000024, For use in conjunction with the FastPack IP TSH Immunoassay and FastPack IP System Analyzer
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0033-2025·2024-10-16

    Medline Blood Pressure Monitor Recalled for Microchip Failure and Overheating

    Medline is recalling approximately 9,608 automatic digital blood pressure units due to a faulty microchip that causes power failures, display issues, and overheating.

    Product
    MEDLINE AUTOMATIC DIGITAL BLOOD PRESSURE UNIT, REF MDS1001U.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0031-2025·2024-10-16

    Aligned Medical Tonsil Packs Recalled Due to Improper-Use Kit Component

    Windstone Medical Packaging is recalling Aligned Medical Tonsil Pack kits due to a component under recall for improper use. Approximately 180 packs were distributed nationwide.

    Product
    Aligned Medical Tonsil Pack REF AMS14809 that contains the Cardinal Health Salem Sump PVC tubes. Product packaged in a convenient manner for use in a general clinical procedure.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-0024-2025·2024-10-16

    Gelato Ice Cream Recalled for Possible Container Fragmentation

    ALCAS USA CORP. is recalling gelato ice cream packaged in compostable tubs due to possible fragmentation of the container material. Affected products were distributed in the USA, Cayman Islands, and Canada.

    Product
    Gelato ice cream packaged in Compostable Tubs which are labeled in part Vaschetta Accoppiata Compostabile . The gelato is packaged in four (4) sizes of Compostable Tubs: COMPOSTABLE YETI TUB 350 GR/ 500 CC (M) (16.90 fl. oz.) COMPOSTABLE YETI TUB 500 Gr/750 CC (25.36 fl. oz.)
    Category
    Food
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0041-2025·2024-10-16

    Inspire Model 4063 Stimulation Lead Labeling Error — Serial Number Mismatch

    Inspire Medical Systems is recalling 457 Model 4063 Stimulation Leads because the serial number on the shelf box does not match the serial number of the device inside, creating identification and traceability issues.

    Product
    Inspire Model 4063 Stimulation Lead, component of the Inspire Upper Airway Stimulation (UAS) system.
    Category
    Medical Device
    Distribution
    Distributed nationwide