The Recall Desk

Agency

National Highway Traffic Safety Administration

NHTSA oversees recalls of vehicles, tires, child seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA campaign number.

Visit the official NHTSA site →

About NHTSA recalls

NHTSA regulates the safety of every motor vehicle sold in the US plus tires, child seats, and motor-vehicle equipment. Recalls are coordinated under a numbering scheme called the NHTSA Campaign Number — a string like 25V123000 where the first two digits are the year, V is for vehicle (T is for tires, C for child seats, E for equipment), and the rest identifies the campaign. Every vehicle in our database can be looked up by VIN to check whether any active campaigns affect it.

NHTSA recalls are unusual in two ways. First, the cause is usually a defined defect or non-compliance with a Federal Motor Vehicle Safety Standard rather than a pathogen or contamination event — so 'severity' tracks the consequence of the defect (does the airbag fail to deploy, does the steering lose assist, does the fuel tank leak) rather than reported illnesses. Second, every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, for as long as the vehicle is on the road. There's no expiration on a NHTSA campaign.

We enrich every recall with the full make / model / year-range affected so you can see at a glance whether your vehicle is in scope. If you're not sure, the VIN lookup decodes your specific vehicle and cross-references the database. The remedy is always free — usually a dealer visit for a part replacement, software update, or inspection.

2001–2025 of 2503

  • HighNHTSA·21V022000·2022-09-01

    2021 Dutchmen Voltage recreational trailers recalled for mislabeled tire pressure

    Keystone RV Company is recalling 2021 Dutchmen Voltage trailers because the Federal Identification Tag incorrectly lists tire pressure as 95 PSI instead of 110 PSI, which could cause underinflated tires and increase crash risk.

    Product
    DUTCHMEN — 2021 DUTCHMEN VOLTAGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V021000·2022-09-01

    2021 Dutchmen Voltage Recreational Trailers Recalled for Incorrect Tire Pressure Label

    Keystone RV Company is recalling 2020–2021 Dutchmen Voltage recreational trailers because the Federal Identification Tag lists incorrect tire pressure (110 PSI instead of 95 PSI), which could cause tire overinflation and increase crash risk.

    Product
    DUTCHMEN — 2021 DUTCHMEN VOLTAGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V908000·2022-08-12

    2023 McLaren Artura recalled for fuel pipe defect increasing fire risk

    McLaren is recalling 164 2023 Artura vehicles because high-pressure fuel pipe nuts may loosen, causing fuel leaks that could lead to fires. Dealers will replace the fuel pipes at no cost.

    Product
    MCLAREN — 2023 MCLAREN ARTURA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V906000·2022-08-12

    2023 KIA Forte front left steering knuckle may crack

    Kia is recalling certain 2023 Forte vehicles due to a manufacturing error that may cause the front left steering knuckle to crack, resulting in loss of steering control and increased crash risk.

    Product
    KIA — 2023 KIA FORTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V997000·2022-08-12

    2022 Entegra Vision Motorhomes Recalled for Melting Wiring Harness

    Jayco is recalling certain 2022 Entegra Vision motorhomes because the main chassis wiring harness may be positioned too close to the exhaust manifold, causing the wiring to melt. This can lead to vehicle stall and increased crash risk.

    Product
    ENTEGRA — 2022 ENTEGRA VISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V909000·2022-08-12

    School buses recalled for incorrectly tightened rear axle fasteners

    Navistar is recalling certain 2023-2024 IC BUS school buses due to fasteners on the rear axle that may have been tightened incorrectly. This can allow the rear axle to shift, reducing vehicle control and increasing crash risk.

    Product
    IC BUS — 2023 IC BUS EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V904000·2022-08-12

    2019-2022 RAM Pickup Trucks Recalled for Defective Tailgate Latch

    Chrysler is recalling 2019-2022 RAM 1500, 2500, and 3500 pickup trucks because the tailgate may not latch properly due to misaligned strikers. An unintended tailgate opening while driving could result in cargo loss and increased crash risk.

    Product
    RAM — 2022 RAM 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V907000·2022-08-12

    Subaru Ascent 2019–2022 Recall for Electrical Fire Risk

    Subaru is recalling 2019–2022 Ascent vehicles due to an improperly fastened ground bolt on the PTC heater that could melt and cause an electrical fire.

    Product
    SUBARU — 2019 SUBARU ASCENT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V825000·2022-08-10

    2021-2022 Audi vehicles recalled for rear-view camera software failure

    Volkswagen Group is recalling certain 2021-2022 Audi vehicles due to a software error that may prevent the rear-view camera from displaying when reversing, potentially reducing driver visibility and increasing crash risk.

    Product
    AUDI — 2021 AUDI A8
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V673000·2022-08-09

    2022 Audi Q3 Fuel Tank Vent Pipe May Leak Gasoline

    Audi is recalling certain 2022 and 2021 Q3 vehicles due to a damaged vent pipe in the fuel tank that may allow gasoline to spill when the fuel cap is opened, increasing the risk of injury.

    Product
    AUDI — 2022 AUDI Q3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V650000·2022-08-08

    Chevrolet Bolt EV battery fire hazard recall for defective modules

    General Motors is recalling 2020-2022 Chevrolet Bolt EV and 2022 Bolt EUV vehicles. The high-voltage battery could catch fire when charged to full or nearly full capacity, increasing risk of injury.

    Product
    CHEVROLET — 2022 CHEVROLET BOLT EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V591000·2022-08-08

    Heartland travel trailers recalled for retractable awning defect

    Heartland is recalling certain 2022-2023 travel trailers with defective electric retractable awnings. The welded seam on the awning fabric may separate, causing the awning to drop beyond normal operation.

    Product
    HEARTLAND — 2022 HEARTLAND SUNDANCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V597000·2022-08-08

    2022 NIU electric scooter firmware defect causes loss of drive power

    Genuine Scooters is recalling 38 units of the 2022 NIU MQiGT EVO scooter due to a firmware issue in the electric motor that may cause loss of drive power, increasing crash and injury risk.

    Product
    GENUINE SCOOTER — 2022 GENUINE SCOOTER NIU MQIGT EVO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V593000·2022-08-08

    Cruiser RV travel trailers recalled for defective awning welds

    Cruiser RV is recalling multiple models of 2022-2023 travel trailers with electric retractable awnings that may fail due to welded seam separation. A failing awning can drop beyond normal operation, creating an injury risk.

    Product
    CRUISER — 2022 CRUISER SHADOW CRUISER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V595000·2022-08-08

    Travel trailers recalled for cooktop gas leak and fire risk

    Airstream is recalling certain 2021-2022 travel trailers because cooktop burner control valves may become damaged and leak gas, creating a fire risk. Owners should contact dealers for free inspection and replacement.

    Product
    AIRSTREAM — 2021 AIRSTREAM INTERSTATE NINETEEN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V594000·2022-08-08

    2022 Ford Maverick side-curtain air bags may not deploy properly

    Ford is recalling 2022 Maverick vehicles because side-curtain air bags may fail to deploy properly during a crash, increasing the risk of injury. Dealers will replace the affected air bag modules free of charge.

    Product
    FORD — 2022 FORD MAVERICK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V649000·2022-08-08

    Chevrolet Malibu and Cadillac XT4 seat belt fastener defects

    General Motors is recalling certain 2016-2021 Chevrolet Malibu and 2019-2021 Cadillac XT4 vehicles because rear seat belt retractors may be improperly secured with loose or missing fasteners, potentially affecting safety in a crash.

    Product
    CHEVROLET — 2020 CHEVROLET MALIBU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V651000·2022-08-08

    2022 Volkswagen Taos Fuel Supply Connector Detachment Recall

    Volkswagen is recalling certain 2022 Taos vehicles because the underhood fuel supply quick-connector may detach from the fuel line, creating fuel leaks that increase risks of engine stalling and fire.

    Product
    VOLKSWAGEN — 2022 VOLKSWAGEN TAOS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V542000·2022-08-07

    2021 Newmar Ventana motorhomes recalled for loose tie rod clamps

    Newmar Corporation is recalling certain 2021 Ventana motorhomes because tie rod clamps may be loose, potentially causing tie rod ends to break or detach and resulting in steering loss.

    Product
    NEWMAR — 2021 NEWMAR VENTANA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V487000·2022-08-07

    Coachmen Freelander Motorhomes Recalled for Propane Valve Defect

    Forest River is recalling certain Coachmen Freelander and other motorhomes due to improperly connected LPG service valves that can cause propane leaks and fire risk. Dealers will inspect and replace valves at no cost.

    Product
    COACHMEN — 2017 COACHMEN FREELANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V492000·2022-08-07

    Roadtrek 2021-2022 Motorhomes: Propane Leak Risk From Valve Defect

    Roadtrek motorhomes from 2021-2022 are being recalled due to a potential propane tank connection defect that may cause propane leaks and fire risk. Contact Roadtrek at 1-888-762-3873 for free repairs.

    Product
    ROADTREK — 2021 ROADTREK ZION
    Category
    Vehicle
    Distribution
    Distributed nationwide