Ceiling-mounted equipment dispensers recalled for weakened suspension arm
IHB Operations is recalling Freedom Boom ceiling-mounted equipment dispensers due to weakened connection points on the suspension arm that could cause equipment failure. The defect affects 1,497 units distributed across multiple US states.
What this means for you
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: FDA Class II medical device with a known structural defect (weakened suspension arm connection) posing significant risk of equipment failure. No injuries or property damage have been reported, meeting the criteria for High severity as a risk-of-harm product without reported incidents.
Plain-English summary
IHB Operations B.V. is recalling Freedom Boom ceiling-mounted utilities and equipment dispensing systems. The affected models include F110, F120, F130, F320, F330, F350, F410, and F420 equipped with 42A Lightweight Spring Arms.
The recalled units have a weakened connection point on the adjustable suspension arm. This defect could potentially cause damage or a break in the suspension system, compromising the device's structural integrity and ability to safely support and dispense equipment from the ceiling.
Approximately 1,497 units have been distributed across multiple US states including Alabama, Arizona, California, Colorado, Connecticut, Florida, Georgia, Illinois, Indiana, Iowa, Louisiana, Massachusetts, Michigan, Minnesota, Missouri, New Jersey, New York, Ohio, Pennsylvania, Tennessee, Texas, Utah, Virginia, Washington, and Wisconsin.
Users of the affected equipment should contact IHB Operations B.V. for guidance regarding inspection, repair, or replacement options.
The recalled product
- Product
- Freedom Boom models series: F110, F120, F130, F320, F330, F350, F410, and F420 with built in 42A Lightweight Spring Arm part numbers 42A-43L, 42A-43M, 42A-43H, and 42A-43S. Ceiling mounted utilities and equipment dispensing system.
- Manufacturer
- IHB OPERATIONS B.V.
- Hazard
- structural-defect
- suspension-failure
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (8)
- UDI-DI: 10841736115951 (F110 SERIES)
- UDI-DI: 10841736115968 (F120 SERIES)
- UDI-DI: 10841736115975 (F130 SERIES)
- UDI-DI: 10841736116491 (F320 SERIES)
- UDI-DI: 10841736116545 (F330 SERIES)
- UDI-DI: 10841736116576 (F350 SERIES)
- UDI-DI: 10841736116590 (F410 SERIES)
- UDI-DI: 10841736116651 (F420 SERIES).
Distribution
Distributed in 36 states:
- AL
- AR
- AZ
- CA
- CO
- CT
- FL
- GA
- IA
- ID
- IL
- IN
- LA
- MA
- MD
- ME
- MI
- MN
- MO
- NC
- NE
- NH
- NJ
- NV
- NY
- OH
- OK
- PA
- TN
- TX
- UT
- VA
- VT
- WA
- WI
- WV
Related recalls
Same category
- SevereMedtronic DLP Retrograde Cannula recalled for sterile barrier breach risk
FDA (Devices) · 2026-05-27
- HighAzurion X-ray System Deaeration Hose May Degrade and Cause Oil Leakage
FDA (Devices) · 2026-05-27
- HighSwan-Ganz Jr Catheter models recalled due to lumen hub leakage
FDA (Devices) · 2026-05-27
- SevereMedtronic DLP Retrograde Cannula Recalls for Sterile Barrier Breach Risk
FDA (Devices) · 2026-05-27
- HighMedtronic DLP Retrograde Cannula Cardiopulmonary Bypass Catheter Recall
FDA (Devices) · 2026-05-27