The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

4226–4250 of 13449

  • HighFDA (Devices)·Z-0697-2025·2024-12-25

    Tracheal Tube Holder Recalled for Defect Causing Potential Skin Pressure Injury

    Medline Industries is recalling 1,464 units of the HUDSON RCI mBrace tracheal tube holder due to adhesive and frame defects that may cause skin pressure injury. The device defect puts pressure on patients' cheekbones and upper lip depending on positioning.

    Product
    HUDSON RCI mBrace, ET Tube Holder with 4 Point Head Strap, REF DYNJMBRC4; tracheal tube fixation device
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0707-2025·2024-12-25

    Duravent Silicone Ventilation Tubes recalled for product substitution error

    Olympus is recalling 984 Duravent Silicone Ventilation Tubes (Model 240075) due to the potential that some units may contain incorrect product—specifically 1.32 mm Tiny T Tubes (Model 70240076) instead of the intended product.

    Product
    Duravent Silicone Ventilation Tube. Model Number: 240075.
    Category
    Medical Device
    Distribution
    18 states
  • HighFDA (Devices)·Z-0689-2025·2024-12-25

    K-Systems T47 Warming Plate may exceed desired temperatures

    The K-Systems T47 Warming Plate has a temperature control defect where warming surfaces may exceed desired set temperatures. CooperSurgical is recalling 22 affected units distributed to fertility clinics.

    Product
    Brand Name: K-Systems Product Name: T47 Warming Plate Model/Catalog Number: K23054 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0703-2025·2024-12-25

    OEC 3D Mobile Fluoroscopic X-Ray System Tube Sealing Defect Recall

    GE OEC Medical Systems is recalling 84 OEC 3D mobile fluoroscopic X-ray systems due to manufacturing defects in X-ray tube sealing that can cause oil leaks and loss of imaging capability.

    Product
    OEC 3D REF Image-Intensified Fluoroscopic X-Ray System, Mobile. The OEC 3D is a mobile fluoroscopic C-Arm imaging system used to assist trained surgeons and other qualified physicians. The system is used to provide fluoroscopic Xray images and volumetric reconstructions durin
    Category
    Medical Device
    Distribution
    44 states
  • HighFDA (Devices)·Z-0695-2025·2024-12-25

    HUDSON RCI mBrace ET Tube Holder Risks Facial Dermal Injury

    Medline is recalling the HUDSON RCI mBrace ET tube holder because defective adhesive and frame elements may cause pressure and skin injury to the face.

    Product
    HUDSON RCI mBrace, ET Tube Holder and 2 Point Head Strap, REF DYNJMBRC2; tracheal tube fixation device
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0704-2025·2024-12-25

    Fluoroscopic X-Ray System Recalled for Insufficient X-Ray Tube Sealing

    GE OEC Elite mobile fluoroscopic X-ray systems are recalled due to insufficient sealing of X-ray tubes, which can cause oil leaks and loss of imaging capability. Approximately 100 systems have been affected.

    Product
    OEC Elite REF Image-Intensified Fluoroscopic X-Ray System, Mobile. The OEC Elite mobile C-arm is intended to provide fluoroscopic and digital spot images of the patient anatomy, interventional tools/devices, and contrast agents during diagnostic, interventional, and surgical
    Category
    Medical Device
    Distribution
    44 states
  • HighFDA (Devices)·Z-0698-2025·2024-12-25

    ET Tube Holder Recalled Due to Skin Pressure Defect Risk

    Medline is recalling HUDSON RCI mBrace ET tube holders because defective adhesive and frame can cause pressure on patients' cheeks and lips, risking skin injury. The risk depends on device positioning.

    Product
    HUDSON RCI mBrace, ET Tube Holder with Bite Block and 4 Point Head Strap, REF DYNJMBRC4B; tracheal tube fixation device
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0687-2025·2024-12-25

    K-Systems G73 Dry Bath Incubator may exceed target temperature

    CooperSurgical is recalling K-Systems G73 Dry Bath Incubators because warming surfaces may exceed the desired set temperature. The device alarms when this occurs.

    Product
    Brand Name: K-Systems Product Name: G73 Dry Bath Incubator Model/Catalog Number: K22065 Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes and embryos), at c
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0710-2025·2024-12-25

    Medical imaging software recall for incorrect DICOM orientation labels

    Mint Lesion software versions 3.10.0 and 3.10.1 may display incorrect orientation labels for certain DICOM medical images. The defect affects 18 units distributed across the US and internationally.

    Product
    mint Lesion, Software Versions: 3.10.0 and 3.10.1.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0692-2025·2024-12-25

    K-Systems Incubator Device Recall: Temperature May Exceed Desired Setting

    CooperSurgical is recalling 34 K-Systems incubator devices used in assisted reproduction procedures. The warming surfaces may exceed the desired set temperature, though the device will alarm if this occurs.

    Product
    Brand Name: K-Systems Product Name: Multiple/unknown Model/Catalog Number: Multiple/unknown Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g.,
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0688-2025·2024-12-25

    K-Systems G85 Mini Incubator May Exceed Desired Temperature

    CooperSurgical recalls 37 K-Systems G85 Mini Incubators because the device warming surfaces may exceed the desired set temperature. The unit alarms when this occurs, but affected serial numbers require verification.

    Product
    Brand Name: K-Systems Product Name: G85 Mini Incubator Model/Catalog Number: K22074 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0709-2025·2024-12-25

    Medical Imaging Software Recall: mint Lesion Orientation Display Malfunction

    Mint Medical is recalling mint Lesion software versions 3.9.0–3.9.5 due to a malfunction that may display incorrect orientation labels for certain medical images. 65 units were distributed in the US and internationally.

    Product
    mint Lesion, Software Versions: 3.9.0 through 3.9.5.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0702-2025·2024-12-25

    Hillrom Temperature Management Controller Power-On Self-Test Error Code Update

    Augustine Temperature Management recalled Hillrom Temperature Management Controllers (Models WC71, WC77, and MP 2083516) due to power-on self-test error code EA POST. No injuries or illnesses reported.

    Product
    Hillrom Temperature Management Controller, MP, Model # 2083516; used in conjunction with Warming Blankets and Mattresses.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0693-2025·2024-12-25

    Bronchoscopic system may lose power due to defective component

    A defective power component in Noah Medical's Galaxy System bronchoscope may cause sudden power loss during procedures, potentially leading to lung injury or pneumotharax.

    Product
    Galaxy System (GAL-001)
    Category
    Medical Device
    Distribution
    16 states
  • HighFDA (Devices)·Z-0686-2025·2024-12-25

    Philips Access Point Software Issue Risks Patient Data Loss

    Philips Smart-Hopping 2.0 Access Points may reset after 82 days, risking loss of patient data and network disconnections. No injuries have been reported.

    Product
    Philips Smart-Hopping 2.0 AP 1.4 GHz. Model Number: 867216
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0684-2025·2024-12-25

    Eclipse PRO Holter Recorders Recalled for Serial Number Mismatch

    Spacelabs Healthcare recalls 13,202 Eclipse PRO Holter recorders due to manufacturing error where the programmed serial number may not match the physical label. Affected devices were manufactured between April 2021 and November 2024.

    Product
    Eclipse PRO REF 98700 The Spacelabs model 98700 is a portable non-invasive Holter recorder intended to record the patient s ambulatory electrocardiogram.
    Category
    Medical Device
    Distribution
    21 states
  • ModerateFDA (Devices)·Z-0685-2025·2024-12-25

    ECG Patch Recorder Serial Number Mismatch - Eclipse Mini

    Spacelabs Healthcare is recalling the Eclipse Mini ECG patch recorder because incorrect serial numbers may be programmed into devices, causing a mismatch between the physical label and internal serial number.

    Product
    Eclipse Mini REF 98900 The Eclipse MINI Model 98900 is a portable non-invasive continuous ambulatory ECG patch recorder intended to record the patient s electrocardiogram.
    Category
    Medical Device
    Distribution
    21 states
  • ModerateFDA (Devices)·Z-0699-2025·2024-12-25

    Femoral Knee Prosthesis Components May Have Incorrect Packaging

    MicroPort Orthopedics recalls EVOLUTION MP femoral knee prosthesis components due to incorrect packaging. The devices are correctly marked internally but may have wrong labels on their packaging.

    Product
    EVOLUTION MP FEMORAL COMPONENT CS/CR POROUS SIZE 5 RIGHT PRIMARY, REF: EFSRP5PR; EVOLUTION MP FEMORAL COMPONENT CS/CR NON-POROUS SIZE 6 LEFT PRIMARY, REF: EFSRN6PL Knee prosthesis component
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0691-2025·2024-12-25

    K-Systems R65 embryo incubator temperature may exceed setpoint

    CooperSurgical's K-Systems R65 Trolley reproductive incubators may experience temperature excursions above desired setpoints, though devices will alarm when this occurs. The FDA issued a Class II recall of 43 units across eight U.S. states.

    Product
    Brand Name: K-Systems Product Name: R65 Trolley Model/Catalog Number: K24012 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes and em
    Category
    Medical Device
    Distribution
    14 states
  • ModerateFDA (Devices)·Z-0701-2025·2024-12-25

    Augustine HOT DOG Temperature Management Controller Instructions Update

    Augustine Temperature Management is issuing an instructions for use update for its HOT DOG warming controllers (Models WC77, WC77D, WC77R) regarding a power-on self-test error code.

    Product
    Augustine Surgical Inc. HOT DOG PATIENT WARMING, Temperature Management Controller, Multiport, Models: 1) Model # WC77, 2) Model # WC77D (Demo), 3) Model # WC77R (Refurbished); used in conjunction with Warming Blankets and Mattresses.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0700-2025·2024-12-25

    HOT DOG Temperature Management Controller Instructions for Use Update

    Augustine Temperature Management is updating instructions for HOT DOG Patient Warming Controllers (Models WC71, WC71R) regarding a power-on self-test error code. The update affects 135 units distributed in the US and Canada.

    Product
    Augustine Surgical Inc. HOT DOG PATIENT WARMING, Temperature Management Controller, Single Port, Models: 1) Model # WC71, 2) Model # WC71R (refurbished); used in conjunction with Warming Blankets and Mattresses.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0679-2025·2024-12-18

    Galaxy Bronchoscope Biopsy Tool Insertion Risk at Sharp Bend Angles

    Noah Medical is recalling Galaxy bronchoscope units due to risk that biopsy tools may require excessive force or fail to pass through the scope channel when the bronchoscope is sharply bent, potentially causing tissue injury or pneumothorax.

    Product
    Galaxy bronchoscope (Product GALB-001) used with Instructions for use, Part: 10000752, part of the Noah Medical Galaxy System (GAL-001)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0665-2025·2024-12-18

    MICRO-X Rover Mobile X-ray System delivers lower-than-set radiation doses

    Micro-X Ltd. is recalling 18 MICRO-X Rover Mobile X-ray Systems because they can deliver lower radiation doses than operators set. The affected units use Control Board PCBA 12425-03 or earlier.

    Product
    MICRO-X Rover Mobile X-ray System, # MXU-RV35; MICRO-X Rover Mobile X-ray System, # MXU-RV71
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0674-2025·2024-12-18

    Convertor Isolation Gowns may fail protective barrier requirements

    Cardinal Health is recalling 940,203 Convertor Isolation Gowns because raw materials may prevent them from meeting AAMI Level 3 protection specifications.

    Product
    Convertor Isolation Gown, AAMI Level 3 protection, Product Codes AT6100, AT6100-XL, AT6200, and AT6200-XL
    Category
    Medical Device
    Distribution
    Distributed nationwide