The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

5676–5700 of 13512

  • HighFDA (Devices)·Z-2489-2024·2024-08-14

    BD PYXIS MEDBANK Automated Cabinet May Print Incorrect Medication Bin Labels

    A software issue in the BD PYXIS MEDBANK automated medication dispensing cabinet can cause incorrect bin labels to be printed for restock operations. This could lead to medication administration errors affecting patient safety.

    Product
    BD PYXIS MEDBANK TWR MN CR-10HH-2FM-P, REF: 169-83 containing software version 3.9.1.9
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2518-2024·2024-08-14

    Gyn Laparoscopy Kits Recalled Due to Inadequate Sterilization Process

    American Contract Systems is recalling 29 gynecological laparoscopy surgical kits due to insufficient aeration during sterilization, which may compromise sterility and increase infection risk for patients.

    Product
    American Contract Systems Gyn Laparoscopy convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2539-2024·2024-08-14

    Medical Device Hookup Instructions Contain Errors Affecting Endoscope Disinfection

    Steris Corporation recalls certain automated endoscope reprocessor hookups due to incorrect instructions in product documentation. Improper hookup connection could prevent proper endoscope disinfection, risking patient infection.

    Product
    Hookup Model/Catalog Number: DSD-110-HU0163 Product Description: Hookups provide the interface between DSD Automated Endoscope Reprocessors ( AER ) and endoscopes, which allow perfusion of liquids dispensed by the AER to contact and high-level disinfect the channels of flexib
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2475-2024·2024-08-14

    GE SIGNA MR355 MRI System Recalled for Potential Implant Overheating Risk

    GE SIGNA MR355 MRI systems running software versions SV25.5 or SV25.6 may cause implant overheating in certain scanning conditions. Risk occurs when using specific imaging sequences with the Optimized T2 FLAIR feature disabled.

    Product
    SIGNA MR355, with affected software versions: SV25.5, SV25.6; Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2496-2024·2024-08-14

    Automated Medication Dispensing Cabinet Software Issue with Incorrect Bin Labeling

    BD PYXIS MEDBANK automated medication dispensing cabinets with software version 3.9.1.9 may generate incorrect bin location labels during restocking. This could cause medications to be placed in wrong storage locations.

    Product
    BD PYXIS MEDBANK TWR MN CR-4HH-5FM-P, REF: 169-91 containing software version 3.9.1.9
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2514-2024·2024-08-14

    Diagnostic Test Kits Recalled for False Vibrio Results With Certain Transport Medium

    BioFire Diagnostics is recalling gastrointestinal diagnostic test kits due to false positive Vibrio results when used with certain transport mediums.

    Product
    BIOFIRE FILMARRAY Gastrointestinal (GI) Panel REF RFIT-ASY-0116 (30 test kit) BIOFIRE FILMARRAY Gastrointestinal (GI) Panel REF RFIT-ASY-0104 (6 kit test) The BIOFIRE FILMARRAY Gastrointestinal (GI) Panel is a qualitative multiplexed nucleic acid-based in vitro diagnost
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2469-2024·2024-08-14

    GE SIGNA Artist MR system may overheat implants in certain sequences

    GE Medical Systems is recalling SIGNA Artist MR imaging systems because they may produce radiofrequency power exceeding user-set limits when using certain imaging sequences in Low SAR Mode, potentially causing MR-conditional implants to overheat.

    Product
    SIGNA Artist, with affected software versions: DV26.0, DV27.1, DV28.1, DV29.1, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2484-2024·2024-08-14

    SIGNA MAGNUS MRI Software Can Overheat Implanted Devices

    GE Medical Systems recalled SIGNA MAGNUS MRI systems with software versions MR29.1 or RX29.1. Under specific imaging conditions in Low SAR Mode, the system may exceed safe radiofrequency power limits and cause implanted medical devices to overheat.

    Product
    SIGNA MAGNUS, with affected software versions: MR29.1, RX29.1; Nuclear Magnetic Resonance Imaging System - research use only
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2481-2024·2024-08-14

    SIGNA UHP MRI System Software Versions May Cause Implant Overheating

    GE Medical Systems is recalling SIGNA UHP MRI systems with software versions RX28.0 or MR30.1. A configuration issue can cause radiofrequency output to exceed prescribed limits, potentially overheating MR conditional implants.

    Product
    SIGNA UHP, with affected software versions: RX28.0, MR30.1; Nuclear Magnetic Resonance Imaging System - research use only
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2460-2024·2024-08-14

    GE SIGNA Pioneer MR Systems May Overheat Patient Implants During Scanning

    GE SIGNA Pioneer MR systems with certain software versions may allow radiofrequency exposure to exceed prescribed limits in Low SAR Mode when using specific imaging sequences, potentially causing overheating of MR conditional implants.

    Product
    SIGNA Pioneer, with affected software versions: PX25.0 to PX25.5, PX26.0, PX26.1, PX28.0 to PX28.4, PX29.0, PX29.1, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2473-2024·2024-08-14

    MR System Software Defect May Cause Implant Overheating During Scanning

    GE SIGNA Explorer MR imaging systems with affected software versions may overheat implants during certain scan sequences. 2,528 units affected worldwide; no injuries reported.

    Product
    SIGNA Explorer, with affected software versions: SV25.5, SV25.6, SV29.2, MR30.0, MR30.1; Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2505-2024·2024-08-14

    Surgical Laser System Recalled Due to Wireless Footswitch Pairing Difficulties

    Olympus Corporation is recalling the Soltive Pro SuperPulsed Laser System due to difficulties pairing its wireless footswitch, which could delay surgical procedures. The recall affects 253 units worldwide.

    Product
    Soltive Pro SuperPulsed Laser System, Model TFL-SLS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2506-2024·2024-08-14

    Wireless Footswitch for Soltive Laser System Recalled for Pairing Difficulties

    Olympus Corporation of the Americas is recalling 1,838 units of the Soltive SuperPulsed Laser System Wireless Footswitch due to pairing difficulties that may delay surgical procedures.

    Product
    Soltive SuperPulsed Laser System Wireless Footswitch, Model TFL-AFSWL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2504-2024·2024-08-14

    Soltive Premium SuperPulsed Laser System Wireless Footswitch Pairing Difficulties

    The Soltive Premium SuperPulsed Laser System may experience difficulties pairing its wireless footswitch, potentially delaying surgical procedures. The recall affects units distributed worldwide.

    Product
    Soltive Premium SuperPulsed Laser System, Model TFL-PLS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2535-2024·2024-08-14

    NavaClick Syringe and Needle Model LIN02 Recalled for Incorrect Carton GTIN Label

    Lineage Biomedical is recalling NavaClick Syringe and Needle Model LIN02 due to an incorrect GTIN number on carton packaging. The recall affects 215 cartons distributed in Michigan and South Carolina.

    Product
    NavaClick Syringe and Needle, Model Number LIN02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2457-2024·2024-08-07

    Arctic Sun Temperature Management System software failure may disable critical safety alarms

    Arctic Sun Temperature Management Systems may fail to reach target temperature and critically fail to alert clinicians. The software defect affects approximately 10,507 units worldwide and risks hypothermia or hyperthermia.

    Product
    Arctic Sun Temperature Management Systems, Name/REF: Arctic Sun STAT, NA/6000-00-00; Arctic Sun STAT Loaner, NA/6000-00-00L; Arctic Sun Stat EU UK/600001; Arctic Sun Stat Taiwan/600006; Arctic Sun Stat Japan/600020; Arctic Sun 5000, NA/5000-00-00; Arctic Sun 5000, NA w/ T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2450-2024·2024-08-07

    Hip Replacement Prosthesis Recalled Due to Increased Postoperative Fracture Risk

    Zimmer hip replacement prostheses are recalled due to increased risk of postoperative femoral fracture. Affected devices are distributed nationwide; patients should consult their surgeon.

    Product
    CPT Hip Joint Metal/Polymer Semi-Constrained Cemented Prosthesis, used in Hip Arthroplasty; Item Numbers 00811400000 00811400010 00811400100 00811400110 00811400200 00811400210 00811400218 00811400230 00811400300 00811400310 00811400318 00811400330 00811400400 008114
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2455-2024·2024-08-07

    Clinical Chemistry Analyzer Software Bugs May Cause Erroneous Patient Results

    Beckman Coulter's DxC 500 AU analyzer has two software bugs that may cause erroneous patient results due to misreported calibrations or expired reagents. No injuries or illnesses have been reported.

    Product
    DxC 500 AU Clinical Chemistry Analyzer, REF C63520 is an automated chemistry analyzer that measures analytes in samples, in combination with appropriate reagents, calibrators, quality control (QC) material and other accessories. This system is for in vitro diagnostic use only.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2456-2024·2024-08-07

    Blood Culture Identification Panel May Produce False Positive Results

    The BIOFIRE BCID2 Panel may produce false positive Serratia marcescens results when used with certain culture media bottles, potentially leading to inappropriate changes in patient therapy.

    Product
    BIOFIRE Blood Culture Identification 2 (BCID2) Panel, REF: RFIT-ASY-0147, for FILMARRAY Systems, when used in conjunction with Culture Media Bottles: BACT/ALERT FA PLUS, REF: 410851, and BACT/ALERT PF PLUS, REF: 410853
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2416-2024·2024-08-07

    SlideView VS200 slide viewer laser shutter malfunction recall

    The SlideView VS200 slide viewer has a broken laser fuse caused by a short circuit from a poorly positioned cable. This prevents the shutter from operating properly, leaving it stuck in an open or closed position.

    Product
    SlideView VS200 slide viewer,
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2451-2024·2024-08-07

    Capio SLIM Suture Capturing Device may fail to catch sutures consistently

    Boston Scientific is recalling some lots of Capio SLIM Suture Capturing Devices because they may not consistently catch sutures during surgery, potentially requiring prolonged procedures or additional medical intervention.

    Product
    Capio SLIM Suture Capturing Device, Box of 5, Outer Package UPN: M0068318261, Inner Package UPN: M0068318260. Capio SLIM Suture Capturing Devices are used by physicians to facilitate the consistent placement of sutures during open surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2458-2024·2024-08-07

    BD Insyte Autoguard BC IV Catheter Recalled for Tubing Defect and Leakage

    Becton Dickinson has recalled certain BD Insyte Autoguard BC IV catheters due to potential holes in the catheter tubing that could cause leakage during insertion. The recall involves 26,400 units distributed in the United States.

    Product
    BD Insyte Autoguard BC, Shielded IV Catheter with Blood Control Technology, REF: 382533, 20 GA x 1.00 in (1.1x25 mm) 63 mL/min, Rx Only. BD Insyte Autoguard BC Shielded IV Catheter is intended to be inserted into a patient's peripheral vascular system for short term use to sample
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2452-2024·2024-08-07

    Boston Scientific Capio SLIM Device May Fail During Surgical Procedures

    Some lots of the Capio SLIM suture capturing device may fail to consistently catch sutures during surgery, potentially requiring extended procedures or additional medical intervention.

    Product
    Capio SLIM Suture Capturing Device, 1-Pack, UPN: M0068318250. Capio SLIM Suture Capturing Devices are used by physicians to facilitate the consistent placement of sutures during open surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2454-2024·2024-08-07

    SOFT-VU KUMPE Catheters Recalled for Mislabeled Inner Pouch

    Angiodynamics is recalling SOFT-VU KUMPE 5F X 65CM angiographic catheters (595 boxes nationwide) because inner pouch labels may show information for a different catheter model while shelf-box labels are correct.

    Product
    SOFT-VU KUMPE 5F X 65CM -Used for patients in need of angiographic diagnosis. Catalog Number: 10732701
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2453-2024·2024-08-07

    SOFT-VU KUMPE Diagnostic Catheter Recalled for Mislabeled Inner Pouch

    Angiodynamics recalls SOFT-VU KUMPE diagnostic catheters because inner pouch labels may show incorrect catheter length information, while the outer box label is accurate. 519 boxes distributed nationwide.

    Product
    SOFT-VU KUMPE 5F X 40CM -Used for patients in need of angiographic diagnosis. Catalog Number: 10732702
    Category
    Medical Device
    Distribution
    Distributed nationwide