The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

8051–8075 of 13652

  • ModerateFDA (Devices)·Z-0263-2024·2023-11-15

    Fixodent Denture Cream Recalled Due to Improper Storage Conditions

    Family Dollar is recalling 329,044 units of Fixodent denture cream products due to improper storage outside labeled temperature requirements. No illnesses or injuries have been reported.

    Product
    FIXODENT ORG CREAM 2.4OZ, SKU 906018 FIXODENT ADH CREAM WITH SCOPE 2OZ, SKU 906402 FIXODENT ORG CREAM TRAVEL .75OZ, SKU 901239
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0269-2024·2023-11-15

    Contact Lens Solution Recalled for Improper Storage Temperature

    Family Dollar's MEDIC's CHOICE contact lens solution was distributed between June and October 2023 due to storage outside labeled temperature requirements. Approximately 329,044 units were affected across 22 states.

    Product
    MEDIC's CHOICE CONTACT LENS SOLUTION 12FLOZ, SKU 998935
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0242-2024·2023-11-15

    Disposable Surgical Forceps Recalled for Incorrect Expiration Date Labeling

    Stryker Corporation is recalling 2,321 units of Disposable Spetzler-Malis Bipolar forceps due to an error in the product label's expiration date. The label indicates a 54-month shelf life when the actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 23CM SM DISP BAYONET 0.5MM TIP, Catalog Number 6760-230-005
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0268-2024·2023-11-15

    ARC Teeth Whitening Pen Recalled Due to Improper Storage

    Family Dollar recalls 329,044 units of ARC Teeth Whitening Pen sold between June and October 2023 across 22 states due to improper storage outside temperature requirements.

    Product
    ARC TEETH WHITENING PEN 0.06 FL OZ, SKU 997950
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0248-2024·2023-11-15

    Disposable Bipolar Forceps Shelf Life Labeling Error Stryker

    Stryker recalls disposable Spetzler-Malis bipolar forceps due to incorrect shelf life labeling. The label states 54 months but the actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 20CM IM DISP BAYONET 0.5MM TIP, Catalog Number 6770-200-005
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0262-2024·2023-11-15

    Family Dollar marijuana test strips recalled over improper storage

    Family Dollar recalled 329,044 at-home marijuana test strips (SKU 900752) due to improper storage outside labeled temperature requirements. Products were distributed across 22 states between June and October 2023.

    Product
    AT HOME MARIJUANA TEST STRIP, SKU 900752
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0285-2024·2023-11-15

    Dental Prophylaxis Cups Recalled Due to Wrong Product in Packaging

    One lot of Contra Gray Soft Turbo Plus dental prophylaxis cups may contain Contra Petite Web LF Soft Purple Cup dental angles instead. The recalled product was distributed in Indiana, Tennessee, and Missouri.

    Product
    CONTRA GRAY (soft) TURBO PLUS CUPS, REF 153112. Dental Prophylaxis Angles
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-0267-2024·2023-11-15

    Denture cleanser tablets recalled due to improper storage conditions

    Family Dollar recalls 329,044 units of GoodSense denture cleanser tablets that were stored outside their labeled temperature requirements. Products were sold between June and October 2023 at Family Dollar stores across 24 states.

    Product
    GOODSENSE DENTURE CLEANSER GRN TAB 40CT, SKU 906312 GOODSENSE DENTURE CLEAN OVRNT TAB 40CT, SKU 906023
    Category
    Medical Device
    Distribution
    23 states
  • SevereFDA (Devices)·Z-0170-2024·2023-11-08

    Senhance Robotic Surgical System uncontrolled arm motion malfunction

    Asensus Surgical recalls 21 units of Senhance Surgical System due to uncontrolled laparoscope arm motion after surgeons disengage remote control. The malfunction has occurred and may recur on affected devices.

    Product
    Senhance Surgical System, which includes: Manipulator Arm, ISU Configuration ( Catalog Number X9007708), Intelligent Surgical Unit (Catalog Number X9007696), and Cockpit, ISU Configuration (Catalog Number X9007707), Software (SW) version 2.7.4; robotic surgical system
    Category
    Medical Device
    Distribution
    5 states
  • SevereFDA (Devices)·Z-0144-2024·2023-11-08

    Stolen McGRATH MAC Video Laryngoscopes Recalled for Failed Quality Tests

    Covidien recalls 5,709 stolen McGRATH MAC video laryngoscopes that failed quality tests. These defective devices risk failed intubation and may compromise airway management.

    Product
    Stolen McGRATH MAC Video Laryngoscopes, REF: 301-000-000
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0216-2024·2023-11-08

    Cepheid Xpert Xpress Strep A test kits may produce invalid results

    Cepheid is recalling 1,413 Xpert Xpress Strep A test kits due to a defect in the included pipettes. Defective pipettes may fail to dispense adequate sample volume, resulting in invalid test results or no test result.

    Product
    Xpert Xpress Strep A, REF:Xprstrepa-CE-10, CE IVD,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0200-2024·2023-11-08

    RX Imola Clinical Chemistry Analyzer rerun feature may report results incorrectly

    RX Imola-IVD Clinical Chemistry Analyzers may report test results incorrectly when handling out-of-range samples due to improper parameter rerun settings. 35 units nationwide are affected.

    Product
    RX Imola-IVD Clinical Chemistry Analyzer Catalog Number: RX4900. RX4900R (refurbished)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0206-2024·2023-11-08

    Oncology Information System Document Values Not Visible in Read-Only Mode

    RayCare oncology information system versions 5B and 6A contain a software bug where document field values do not display when documents are opened in read-only mode outside the Documents workspace.

    Product
    RayCare 5B and 6A including service packs- An oncology information system used to support workflows and scheduling, as well as clinical information, planning and treatment management for oncology care Product name (build number): (1)RayCare 5B SP1 (5.1.1.60246); (2)RayCare 5B
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0215-2024·2023-11-08

    Cepheid Xpert Xpress Strep A test kits may produce invalid results

    Cepheid is recalling Xpert Xpress Strep A test kits because pipettes may fail to dispense adequate sample volume, potentially resulting in invalid or absent test results.

    Product
    Xpert Xpress Strep A, XPRSTREPA-10, P/N: 302-2294 IVD, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0187-2024·2023-11-08

    AZUR CX 35 Peripheral Coil System Detachable Recalled for Unsealed Pouch Packaging

    MicroVention is recalling 14 units of the AZUR CX 35 Peripheral Coil System due to unsealed pouch packaging that could compromise device sterility. The affected units were distributed across eight states.

    Product
    AZUR CX 35 Peripheral Coil System Detachable 13mm x 24 CM, REF: 45-751324
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0203-2024·2023-11-08

    Coapt Dome Electrode Gen2 System Recalled for Burn Risk

    Coapt LLC is recalling the Dome Electrode Gen2 system due to potential burns or blistering from exposure to sunlight, warm temperatures exceeding 12 hours, or battery damage.

    Product
    Coapt Dome Electrode, Gen2 system, cutaneous electrode
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0213-2024·2023-11-08

    Orthopedic knee implant components mislabeled; size mix-up risk

    Corin Ltd recalled 3 Unity CR Femur knee implants due to labeling errors. Size 6 implants from batch 529803 may be labeled as size 7, and vice versa.

    Product
    Unity CR Femur Right, Size 6, Model Number 112.001.32 Primary and revision total knee arthroplasty
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0168-2024·2023-11-08

    McGrath Mac 2 Laryngoscope Blade Recalled for Anti-Fog Agent Defect

    Covidien is recalling McGrath Mac 2 disposable laryngoscope blades due to defective anti-fog coating that can cause condensation and vision obstruction. Approximately 42,367 units were distributed across the United States and internationally.

    Product
    McGrath Mac 2, Disposable Laryngoscope Blade, REF: 350-017-000, Sterile EO, Rx Only
    Category
    Medical Device
    Distribution
    38 states
  • HighFDA (Devices)·Z-0202-2024·2023-11-08

    RX Monaco-IVD Clinical Chemistry Analyzer rerun feature may report incorrect results

    Randox Laboratories is recalling 13 RX Monaco-IVD Clinical Chemistry Analyzers with a rerun feature defect that may report incorrect test results when samples are outside normal assay range. Units were distributed nationwide including Puerto Rico.

    Product
    RX Monaco-IVD Clinical Chemistry Analyser Catalog Number: RX5000
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0207-2024·2023-11-08

    Blood Gas Analyzer Software Issue Causes Erroneous Creatinine Results During Startup

    Nova Biomedical Prime Plus Analyzers may report incorrect creatinine levels during the first 2-4 hours after installing a new sensor cartridge. These errors may not be identified by traditional quality control practices.

    Product
    Nova Biomedical Prime Plus Analyzer -Intended to measure certain gases in blood, serum, plasma or pH of blood, serum, and plasma. (1) PN 57400 Stat Profile Prime Plus Analyzer (2) PN 59508 Stat Profile Prime Plus Analyzer, Remanufactured
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0198-2024·2023-11-08

    RX Daytona Plus clinical chemistry analyzer may report incorrect test results

    The RX Daytona Plus clinical chemistry analyzer may report incorrect results when samples fall outside normal range and the automatic rerun feature malfunctions. Randox Laboratories is recalling 5 units distributed nationwide.

    Product
    RX Daytona Plus (with ISE)-IVD Clinical Chemistry Analyser Catalog Number: RX4040
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0196-2024·2023-11-08

    Siemens X-Ray Systems Software Issue May Cause Patient Misdiagnosis

    Siemens Medical Solutions USA is recalling 367 mobile X-ray systems (186 Cios Flow and 181 Cios Spin) due to a software issue that may result in patient misdiagnosis and repeat radiation exposure. Affected units were distributed nationwide.

    Product
    ***Updated 12/4/23*** (1) Cios Flow (VA30) mobile fluoroscopic C-arm X-ray System. Designed for the surgical environment and provides comprehensive image acquisition modes. Material Number: 11108110 (2)Cios Spin- a mobile x-ray system designed to provide x-ray imaging of
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0208-2024·2023-11-08

    POC Analyzer Risk of Erroneous Creatinine Results During Cartridge Startup

    Nova Biomedical's Stat Profile Prime Plus POC analyzer may report inaccurate creatinine results during the first 2-4 hours after sensor cartridge installation. Standard quality control checks may not detect these errors.

    Product
    Nova Stat Profile Prime Plus POC Analyzer (CE)-Intended to measure certain gases in blood, serum, plasma or pH of blood, serum, and plasma. (1) PN 63368 Stat Profile Prime Plus POC Analyzer (2) PN 63369 Stat Profile Prime Plus POC Analyzer, Remanufactured P/N: 57400, 633
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0201-2024·2023-11-08

    RX Modena Clinical Chemistry Analyzer Recalled for Incorrect Rerun Results

    Randox Laboratories is recalling the RX Modena-IVD Clinical Chemistry Analyzer nationwide due to parameter re-run settings that may fail to function correctly when samples are outside the assay range, potentially resulting in incorrect test results.

    Product
    RX Modena-IVD Clinical Chemistry Analyser Catalog Number: RX9000
    Category
    Medical Device
    Distribution
    Distributed nationwide