The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

10826–10850 of 31361

  • HighFDA (Food)·F-0042-2025·2024-10-23

    Seasoned Dried Whiting with Undeclared Wheat Allergen Recalled

    Lemonland Food Corp recalls Seasoned Dried Whiting due to undeclared wheat allergen. Consumers with wheat allergies should discard or return the product.

    Product
    Item FLD1004A, Seasoned Dried Whiting, distributed in plastic clamshell containers, net wt. 0.315lb. The H-Mart label declares: Dried Pollack, Starch Syrup, Soy Sauce, Red Pepper Powder, Sesame Seeds.
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-0067-2025·2024-10-23

    Grabeez snack mix recalled for undeclared almonds and cashews

    Grabeez The Big Cheese snack mix contains undeclared almonds and cashews that pose an allergen risk. The product was distributed to warehouses, retail facilities, and healthcare facilities across multiple states.

    Product
    Grabeez The Big Cheese SNACK MIX Net Wt. 3.25 oz (92g) Ingredients: Peanuts***Cheese Pretzel Gems***Vegetable Shortening***Snackin' Mix***Cheez-It Crackers***Cheese Wicks***Contains Milk, Peanuts, Soy, Wheat and Sesame. Truly Good Foods, Charlotte, NC 28273
    Category
    Food
    Distribution
    11 states
  • HighFDA (Devices)·Z-0122-2025·2024-10-23

    Medline Open Heart Surgical Kit Recall for Model Labeling Error

    Medline Industries recalls certain open-heart surgical kits (Lot 23LBR364) due to incorrect model labeling, where model 30001 units were labeled as model 30000. The recall affects 30 units distributed nationwide.

    Product
    MEDLINE OPEN HEART, REF DYNJ904261B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0086-2025·2024-10-23

    Leica Biosystems Cryostat lacks warning for flammable freezing spray use

    Leica Biosystems Cryostat Model CM1510 S is recalled due to missing warning labels about flammable freezing sprays, which can ignite and cause serious injury. The device labeling lacked fire hazard warnings prior to 2019.

    Product
    Leica Biosystems Cryostat Model Number CM1510 S, Material Numbers: a) 491510C002, b) 1491510C003; for freezing and sectioning tissue samples
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0104-2025·2024-10-23

    Boston Scientific AVVIGO+ Guidance System Recalled for Grid Overlay Display Error

    Boston Scientific is recalling AVVIGO+ systems due to a software anomaly that displays an incorrect grid overlay when connected to OptiCross 18 catheters, potentially leading to vessel imaging misinterpretation.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM EU + ROW; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities which inc
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0118-2025·2024-10-23

    Beckman Coulter Recalls Immunochemistry IGM Reagent Lots for Sensitivity Failure

    Beckman Coulter is recalling two lots of IGM reagent used in IMMAGE immunochemistry systems because they don't meet sensitivity specifications. The reagent measures immunoglobulin M levels in blood samples.

    Product
    IMMAGE Immunochemistry Systems IGM Immunoglobulin M Reagent REF 447610 IGM reagent, when used in conjunction with IMMAGE Immunochemistry Systems and Calibrator 1, is intended for the quantitative determination of immunoglobulin M (IGM) in human serum by rate nephelometry.
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-0107-2025·2024-10-23

    [pending] Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM EVAL US; the system ut

    Pending LLM rewrite. Source: FDA_DEVICE Z-0107-2025.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM EVAL US; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities which incl
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0127-2025·2024-10-23

    Horizon Cardiology Hemodynamic System Recalled for Configuration Error

    Horizon Cardiology Hemo Version 12.2 is recalled for a unit-of-measurement configuration issue that can produce incorrect hemodynamic calculations, potentially resulting in misdiagnosis and inappropriate treatment. The recall affects 3 worldwide systems.

    Product
    Horizon Cardiology Hemo. Version 12.2.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0121-2025·2024-10-23

    Open Heart Surgical Kit Recalled for Incorrect Vessel Cannulae Model Labeling

    Medline Industries is recalling 123 kits of its Open Heart Pack after discovering that model 30001 vessel cannulae were incorrectly labeled as model 30000. This labeling error could lead to use of the wrong surgical instrument during open heart procedures.

    Product
    MEDLINE OPEN HEART PACK, REF DYNJ66216C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0066-2025·2024-10-23

    DiamondTOUCH Digital Inflation Device Sterile Barrier Defect Recall

    Merit Medical Systems is recalling the DiamondTOUCH Digital Inflation Device due to a small hole in the sterile barrier. The defect may expose patients to pathogens or pyrogens, potentially causing infection.

    Product
    DiamondTOUCH Digital Inflation Device, REF: IN9135/A, IN9152/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0105-2025·2024-10-23

    Boston Scientific AVVIGO+ Multi-Modality Guidance System Grid Display Software Defect

    Boston Scientific is recalling the AVVIGO+ Guidance System for a software defect that displays incorrect grid overlays when connected to OptiCross 18 catheters. The error affects Live and Record modes only; no injuries have been reported.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM EVAL - ZERO COST US; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalitie
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0114-2025·2024-10-23

    Boston Scientific AVVIGO+ Cardiac Imaging System Grid Display Error

    A software anomaly in Boston Scientific's AVVIGO+ system causes an incorrect 9-grid overlay to display instead of the correct 15-grid overlay when connected to OptiCross 18 catheters, potentially affecting clinical interpretation of vascular imaging.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO II TO AVVIGO MOB UPGRADE EU ROW; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0099-2025·2024-10-23

    Boston Scientific imaging system software error in grid overlay display

    Boston Scientific AVVIGO+ imaging system has a software error causing incorrect grid overlay display in Live and Record modes, potentially affecting depth reference during vascular procedures. 2 units are recalled.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + INT SYSTEM JAPAN; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities which includ
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0095-2025·2024-10-23

    Boston Scientific AVVIGO+ Imaging System Grid Overlay Display Error

    A software anomaly in the Boston Scientific AVVIGO+ Multi-Modality Guidance System causes an incorrect grid overlay display when used with certain catheters. The wrong overlay may lead to incorrect measurement references during imaging procedures.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO+ BRIDGE TO INTEGRATED KIT; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities which
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0010-2025·2024-10-23

    Cisplatin Injection Vials Recalled for Failed Impurity and Degradation Standards

    Accord Healthcare is recalling 11,214 vials of Cisplatin Injection due to failed impurity and degradation specifications. The recalled lot was distributed nationwide in the United States and Puerto Rico.

    Product
    CISPLATIN — CISPLATIN (CISPLATIN)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0068-2025·2024-10-23

    BlueFIRE Inflation Device Recalled for Sterile Barrier Defect Risk

    BlueFIRE Inflation Devices may have a small hole in the sterile barrier, potentially exposing patients to pathogens that could cause infection. Contact your healthcare provider if you received this device.

    Product
    BlueFIRE Inflation Device, REF: IN10140
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0070-2025·2024-10-23

    Custom Inflation Kits Recalled Due to Sterile Barrier Defect and Infection Risk

    Merit Medical Systems is recalling Custom Inflation Kits due to a small hole in the sterile barrier that could expose users to pathogens and pyrogens, increasing infection risk.

    Product
    Custom Inflation Kit, REF: K05-00052M, K05-00053H, K05-00109G, K05-00137K, K05-00296L, K05-00399D, K05-00404C, K05-00410G, K05-00438G, K05-00502F, K05-00564L, K05-00587D, K05-00612Q, K05-00704F, K05-00724F, K05-00793B, K05-00798, K05-00890D, K05-00890D, K05-00944D, K05-00956D, K0
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0049-2025·2024-10-23

    KINOVA Jaco assistive robot recalled for potential fire hazard

    Kinova Inc is recalling 949 KINOVA Jaco assistive robots due to a potential fire hazard that may occur if a damaged robot arm interacts with a wheelchair exhibiting electrical leakage.

    Product
    KINOVA Jaco assistive robot. Model Numbers: PJ 0000 0001, PJ 0000 0012, PJ 0090 0001, PJ 0090 0006, KR MJ2 0001. Jaco replaces the function of the upper limb on one side of the body.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0030-2025·2024-10-23

    Premium Grapenut Special Frozen Dessert Recalled for Undeclared Yellow 5 and 6

    Today's Frozen Desserts, Inc. is recalling Premium Grapenut Special frozen dessert sold in Florida because it contains undeclared Yellow 5 and Yellow 6 artificial colorants that are not listed on the label.

    Product
    Premium Grapenut Special, packaged in paper and plastic containers in sizes 3 Gallons, half gallons, and quarts. Keep Frozen
    Category
    Food
    Distribution
    0 states
  • HighFDA (Devices)·Z-0088-2025·2024-10-23

    Leica Cryostat Model CM1900 Lacks Warning on Flammable Sprays

    Leica Biosystems is recalling the Cryostat Model CM1900 because its labeling lacks a warning about using flammable freezing sprays in the chamber. The sprays can ignite, creating a serious fire and burn hazard.

    Product
    Leica Biosystems Cryostat Model Number CM1900, Material Numbers: a) 14045227382, b) 14901900100, c) 14901900700, d) 1491900UVU2; for freezing and sectioning tissue samples
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0073-2025·2024-10-23

    Merit Medical StabiliT TOUCH Syringe Sterile Barrier Defect Recall

    Merit Medical Systems is recalling 202 StabiliT TOUCH Syringes with potential small holes in the sterile barrier. Affected devices may expose users to pathogens and pyrogens, which could cause infection.

    Product
    StabiliT TOUCH Syringe, REF: IN8VCF/B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0053-2025·2024-10-23

    Dietary supplement with Rauwolscine recalled for potential Salmonella contamination

    Gorilla Mind Rauwolscine dietary supplement is recalled nationwide due to potential Salmonella contamination. Consumers should not use the product and contact the manufacturer.

    Product
    Gorilla Mind Rauwolscine Dietary Supplement, Suppress Appetite, Increased Fat Loss, Increased Energy, dosage 3mg, 90 capsules per bottle, UPC 8 50017 02016 0. Product is manufactured for Gorilla Mind LLC 7154 W. State Street, STE 138, Boise, ID. Product label declares "***Suppl
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0009-2025·2024-10-23

    Duloxetine 20mg Delayed-Release Capsules Recalled for N-Nitroso Impurity

    Breckenridge Pharmaceutical is recalling 7,107 bottles of Duloxetine 20mg delayed-release capsules nationwide due to N-nitroso-duloxetine impurity exceeding FDA interim limits. No illnesses have been reported.

    Product
    DULOXETINE — DULOXETINE (DULOXETINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0117-2025·2024-10-23

    Graft Tube shaft may detach from funnel head during surgical use

    Spineology is recalling 190 Graft Tubes because the shaft may detach from the funnel head when not used as instructed, potentially compromising spinal surgical procedures.

    Product
    The Graft Tube is an optional instrument which, as designed, can be filled with flowable graft material, then advanced through the Access Portal. A Push Rod is then used to facilitate the manual deployment of the graft material out of the Graft Tube and adjacent to where the impl
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0125-2025·2024-10-23

    Cortera spinal fixation system screws recalled due to manufacturing specification concerns

    XTANT Medical is recalling 330 Cortera spinal fixation system screws marked 'DNI' because they may not have been manufactured to specification and could lack adequate strength if implanted.

    Product
    Cortera Spinal Fixation System Screw, Poly, Solid, 6.5mm x 45mm, REF: 150100-65045
    Category
    Medical Device
    Distribution