The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

12526–12550 of 31371

  • HighFDA (Devices)·Z-2346-2024·2024-07-17

    Hemodialysis System Blood Pump Rotor Recall Due to Loose Sheaves

    Fresenius is recalling blood pump rotors in home hemodialysis systems due to loose or dislodged guide sheaves reported during clinical use. The defect could affect proper pump operation during dialysis treatment.

    Product
    RTL190904: 2008K@HOME HEMODIALYSIS SYSTEM W/ BIBAG - Blood Pump Rotor spare part, Model Number: F40015481 Rev A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2316-2024·2024-07-17

    GE Vivid Ultrasound Systems Display Incorrect Patient Names

    GE Vivid ultrasound systems may display incorrect patient information due to slow DICOM response times. Seven affected units were distributed to healthcare facilities in IL, MA, NM, NY, and OK.

    Product
    GE Vivid Ultrasound products, Model Numbers: a) Vivid E90, H45581LB; b) Vivid E95, H45581DA
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-2297-2024·2024-07-17

    Total Knee Procedure Kit Recalled for Excess Ethylene Oxide Residue

    American Contract Systems Inc is recalling a knee surgery procedure kit (24 units, Lot 939241) due to ethylene oxide sterilization residues in the cast padding exceeding safety exposure limits for permanent-implant devices.

    Product
    TOTAL KNEE - 297835 -Procedure Kit Catalog Number: RGTK10L
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2335-2024·2024-07-17

    Ophthalmic injection kit recalled over sterilization confirmation failure

    MICROspecialties recalls 780 units of the Synergetics I Pack Injection Kit (Model 18069) because the company could not confirm proper sterilization, creating risk of post-operative or injection-site infections.

    Product
    Synergetics I Pack Injection Kit Custom-Tray for use with Ophthalmic injections Model/Catalog Number: 18069 Product Description:
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2286-2024·2024-07-17

    Procedure Tray Recalled Due to Excess Sterilization Residue

    American Contract Systems Inc is recalling HAND WRIST FOREARM-LF Procedure trays due to ethylene oxide sterilization residues exceeding safe limits for permanent exposure devices.

    Product
    HAND WRIST FOREARM-LF Procedure tray Catalog Number: CCHD17B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2344-2024·2024-07-17

    Blood Pump Rotor Spare Part Recall Due to Loose Guide Sheaves

    Fresenius is recalling 17 Blood Pump Rotor spare parts nationwide due to loose or dislodged guide sheaves that develop after use. The affected rotor components are used in K@HOME dialysis machines.

    Product
    RTL190395: 2008K@HOME MACHINE, SHORT CAB,OLC/DP,HP - Blood Pump Rotor spare part, Model Number: F40015481 Rev A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2304-2024·2024-07-17

    Arthroscopy Procedure Kit Recalled Due to Ethylene Oxide Residue

    American Contract Systems Inc is recalling 27 arthroscopy procedure kits because ethylene oxide and ethylene chlorohydrin residuals in the cast padding exceeded safe exposure limits for permanent implants.

    Product
    ARTHROSCOPY PACK-Procedure Kit Catalog Number: TNAR22V
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2340-2024·2024-07-17

    Blood Pump Rotor for Hemodialysis System Recalled for Loose Components

    Fresenius Medical Care is recalling Blood Pump Rotor components used in hemodialysis systems after reports of loose or dislodged guide sheaves during use. The defect affects 372 units distributed nationwide and in Canada.

    Product
    190904 2008K@HOME HEMODIALYSIS SYSTEM W/ BIBAG - Blood Pump Rotor spare part, Model Number: F40015481 Rev A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2310-2024·2024-07-17

    Hand Procedure Kit Recalled for Excess Ethylene Oxide Residuals

    American Contract Systems recalls HAND PACK-Procedure Kits due to excess ethylene oxide and ethylene chlorohydrin residuals on the cast padding component, exceeding safe permanent-contact exposure limits.

    Product
    HAND PACK-Procedure Kit Catalog Number: WEHD16B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2345-2024·2024-07-17

    Hemodialysis Blood Pump Rotor Spare Part Recalled for Loose Sheaves

    Fresenius Medical Care is recalling hemodialysis blood pump rotor spare parts due to reports of loose or dislodged guide sheaves. The affected model is distributed nationwide in the U.S. and Canada.

    Product
    RTL190828: 2008K@HOME HEMODIALYSIS SYSTEM - Blood Pump Rotor spare part, Model Number: F40015481 Rev A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2318-2024·2024-07-17

    Dental abutment recall due to incorrect product packaging and labeling

    Preat Corp recalled 7 units of 9006767 Astra EV 4.8mm Milled Titanium Abutments due to incorrect products being packaged and labeled. Affected units were distributed in California, Missouri, and Nevada.

    Product
    9006767 Astra EV 4.8mm Milled Titanium Abutment Milled abutments are too be used in conjunction with an endosseous dental implant fixture to aid in prosthetic rehabilitation.
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-2290-2024·2024-07-17

    Total knee prosthesis recalled for excess ethylene oxide residuals

    American Contract Systems Inc is recalling 272 units of its TOTAL KNEE prosthesis nationwide due to ethylene oxide and ethylene chlorohydrin residuals in the cast padding component that exceed safe limits for permanent implants.

    Product
    TOTAL KNEE, ST LUKES Catalog Number: LMTK17AP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0590-2024·2024-07-17

    Bupropion Extended-Release Tablets Recalled for Dissolution Failure

    Amerisource Health Services is recalling Bupropion Hydrochloride 150mg extended-release tablets nationwide due to dissolution specification failures. The tablets dissolve faster than specified limits.

    Product
    BUPROPION HYDROCHLORIDE — BUPROPION HYDROCHLORIDE (BUPROPION HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2347-2024·2024-07-17

    Blood Pump Rotor Spare Parts Recalled for Loose Guide Sheaves

    Fresenius Medical Care recalls 6 blood pump rotor spare parts used in dialysis machines due to loose or dislodged guide sheaves that developed after clinical use.

    Product
    RTLR190395: 2008K@HOME MACHINE, SHORT CAB,OLC/DP,HP - Blood Pump Rotor spare part, Model Number: F40015481 Rev A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2285-2024·2024-07-17

    Foot-Ankle Procedure Tray Recalled for Excessive Sterilization Residue

    American Contract Systems Inc is recalling 107 units of FOOT ANKLE-LF Procedure tray distributed nationwide due to ethylene oxide and ethylene chlorohydrin residuals exceeding safety limits for permanent-implant devices.

    Product
    FOOT ANKLE-LF Procedure tray Catalog Number:CCFA51B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2274-2024·2024-07-17

    Arthroscopy Pack Recalled for Excessive Sterilization Chemical Residue

    American Contract Systems is recalling 345 units of the AHAR50K Standard Arthroscopy Pack due to ethylene oxide residue levels exceeding regulatory limits. Affected lot numbers are 638231, 962241, and 898241.

    Product
    AHAR50K STANDARD ARTHROSCOPY PACK - 291852. Procedure tray Catalog Number: AHAR50K
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2301-2024·2024-07-17

    Surgical Knee Arthroscopy Kit Recalled for Excessive Sterilization Gas Residuals

    American Contract Systems Inc is recalling its KNEE ARTHROSCOPY-Procedure Kit nationwide due to ethylene oxide and ethylene chlorohydrin residuals exceeding safe limits for permanent medical devices. The recall affects 28 units with lot numbers 975241 and 920241.

    Product
    KNEE ARTHROSCOPY-Procedure Kit Catalog Number: SLAR14G
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2307-2024·2024-07-17

    CUSTOM KNEE Medical Device Procedure Kit recalled for excess chemical residuals

    American Contract Systems Inc is recalling 174 units of the CUSTOM KNEE - 206061-Procedure Kit due to ethylene oxide and ethylene chlorohydrin residuals in the cast padding component. The residuals exceed the safety limits specified in ANSI/AAMI/ISO 10993-7:(R)2012 for permanent-contact medical devices.

    Product
    CUSTOM KNEE - 206061-Procedure Kit Catalog Number: UDKN68AE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2282-2024·2024-07-17

    Procedure Tray Recalled for Excessive Ethylene Oxide Residuals

    American Contract Systems Inc is recalling 129 units of ARTHO KNEE BAPTIST SOUTH PACK Procedure trays (lot numbers 953241, 882241) due to ethylene oxide and ethylene chlorohydrin sterilization residuals exceeding safe limits for permanent-contact medical devices.

    Product
    ARTHO KNEE BAPTIST SOUTH PACK Procedure tray Catalog Number: BPKA49B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2320-2024·2024-07-17

    Medical examination gloves recalled for skin irritation and disintegration

    SVS LLC is recalling 155,540 boxes of non-sterile nitrile examination gloves due to reported skin irritation, glove disintegration with certain cleaning solutions, and size mislabeling. Gloves were distributed nationwide across eight U.S. states.

    Product
    Non-sterile, single use, disposable gloves intended for medical purposes to be worn on the hands of examiners to prevent contamination between a patient and an examiner. The gloves are nitrile, powder-free, ambidextrous, and blue-colored with a beaded cuff. The range of sizes inc
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2323-2024·2024-07-17

    Welch Allyn CP150 Electrocardiograph recalled for missing electromagnetic interference absorber

    Baxter Healthcare is recalling the Welch Allyn CP150 Electrocardiograph because a critical manufacturing step—installation of an electromagnetic interference absorber—was omitted. This could cause device malfunction or interference with nearby medical equipment.

    Product
    Welch Allyn CP150 Electrocardiograph with Spirometry Option, Product Code: CP150A-1ENB. The Electrocardiograph is one of the tools that clinicians use to evaluate, diagnose, and monitor patient cardiac function.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2342-2024·2024-07-17

    Blood Pump Rotor Spare Part Recalled for Loose Guide Sheaves

    Fresenius Medical Care recalls a blood pump rotor spare part used in dialysis systems in Canada due to reports of loose or dislodged guide sheaves after use. No injuries have been reported.

    Product
    191014: 2008K@HOME HD SYSTEM W/BIBAG (CANADA) - Blood Pump Rotor spare part, Model Number: F40015481 Rev A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2337-2024·2024-07-17

    Endoscopic Vessel Harvesting System Recalled for Altered Component Spacing

    Maquet Cardiovascular is recalling 600 units of the VASOVIEW HEMOPRO Endoscopic Vessel Harvesting System due to reports of C-Ring wire straightening and altered spacing between components. No adverse events have been reported.

    Product
    The VASOVIEW HEMOPRO Endoscopic Vessel Harvesting Systems is designed for use in conjunction with the 7 mm Extended Length Endoscope. The Harvesting Cannula has four lumens which house the Endoscope, C-Ring, distal lens washer tube, and harvesting tool for cutting and cauterizin
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2277-2024·2024-07-17

    Procedure Tray Recalled for Excess Ethylene Oxide Residue

    American Contract Systems is recalling a lower extremity procedure tray (48 units) due to ethylene oxide residuals that exceed FDA safety limits for permanent exposure medical devices.

    Product
    LOWER EXTREMITY - 247542- Procedure tray Catalog Number: BFLE56X
    Category
    Medical Device
    Distribution
    Distributed nationwide