The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

12626–12650 of 27721

  • SevereFDA (Devices)·Z-1642-2024·2024-05-22

    Boston Scientific Cardiac Catheters Recalled for Material Delamination

    Boston Scientific is recalling certain Expo 5F cardiac catheters due to polyurethane layer delamination and material detachment that may prevent guidewire advancement during procedures. The recall affects 290 catheters distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FR6 (5PK), REF H74908526042; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1649-2024·2024-05-22

    Cardiac Catheters Recalled Due to Material Delamination and Guidewire Failure

    Boston Scientific is recalling Expo 5F cardiac catheters due to material delamination in the inner lining that prevents guidewire advancement. The defect affects 25,617 units distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO IM (5PK), REF H749085262012; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1667-2024·2024-05-22

    Expo 5F Angiographic Catheters Recalled for Guidewire Advancement Failure

    Boston Scientific is recalling certain batches of Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment that prevents guidewire advancement through the device.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO MULTIPACK 145 (SGL), REF H749085263011; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1652-2024·2024-05-22

    Cardiac Catheters Recalled Due to Delamination and Device Malfunction

    Boston Scientific is recalling 8,725 Expo 5F Selective Angiographic Catheters worldwide due to polyurethane layer delamination and material detachment that prevents guidewire advancement.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO FL3 (5PK)REF H7490852620A2; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1666-2024·2024-05-22

    Boston Scientific Expo 5F catheters recalled for material delamination

    Boston Scientific recalls Expo 5F Selective Angiographic Catheters due to polyurethane layer delamination and material detachment that can prevent guidewire advancement. The recall affects 46,860 units distributed worldwide.

    Product
    Expo 5F Selective Angiographic Catheters, MODEL - 5F EXPO MULTIPACK (5PKX3), REF H749085263002; cardiac catheter
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1827-2024·2024-05-22

    Philips Patient Information Center iX Software: Event Catalog Data Loss Recall

    Philips Patient Information Center iX software version 4.x fails to properly save or transfer event catalog information, risking data loss in healthcare facilities. The FDA issued a Class II recall affecting 358 units globally.

    Product
    Patient Information Center iX and Patient Information Center iX Expand, Software Version 4.x.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1830-2024·2024-05-22

    Philips Ingenia 3.0T MR Systems May Not Warn of Low Ventilation Settings

    Philips Ingenia 3.0T MR systems with software R5.7.1 may fail to warn about low ventilation, potentially causing patient overheating or burning sensations. 19 units affected worldwide.

    Product
    Ingenia 3.0T with Evolution Upgrade 3.0T - - Magnetic Resonance (MR) systems are Medical Electrical Systems indicated for use as a diagnostic device REF: 782117
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1806-2024·2024-05-22

    MEDLINE namic Cardiovascular Kit Variants Recalled for Lack of Sterility

    Medline Industries recalls multiple namic CONVENIENCE KIT variants used in cardiovascular procedures due to lack of sterility assurance. Approximately 570 units distributed nationwide may pose infection risk.

    Product
    namic CONVENIENCE KIT, a) CAROTID MANIFOLD KIT, REF 60011045; b) 3V MANIFOLD KIT ON WITH NAMIC DT & WASTE MANAGEMENT, REF 60070582; c) LEFT HEART KIT, REF 60071822; d) LEFT HEART KIT, REF 60080085; e) CONVENIENCE KIT, REF 60100055; f) CONVENIENCE KIT, REF 60101041;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1804-2024·2024-05-22

    Medtronic Suction Tubes Recalled for Potential Unsealed Sterile Packaging

    Medtronic is recalling multiple models of suction tubes due to potential for unsealed sterile packing, which could compromise device sterility. Affected customers should refer to the official FDA recall notice for lot details.

    Product
    Medtronic Suction Tubes: a) DLP¿ Suction Tube 6-Fr. Shaft with Frazier Tip, Model Number: 10050, b) DLP¿ Suction Tube 6-Fr. Shaft with 10-Fr. Soft Tip, Model Number: 10052, c) DLP¿ Suction Tube 6-Fr. Shaft with 10-Fr. Soft Tip, Model Number: 10053, d) DLP¿ Suction Tube
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1832-2024·2024-05-22

    EchoTip Ultra HD Endoscopic Ultrasound Access Needle recalled for elevated bacterial endotoxin

    Cook Medical has recalled EchoTip Ultra HD Endoscopic Ultrasound Access Needles (lots C2145003, C2144407) due to elevated levels of bacterial endotoxin. The devices were distributed internationally in Germany, Netherlands, Switzerland, and the United Kingdom.

    Product
    EchoTip¿ Ultra HD Endoscopic Ultrasound Access Needle, ECHO-HD-19-A, G52012
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Drugs)·D-0496-2024·2024-05-22

    Antibiotic Cefdinir Oral Suspension Recalled for Foreign Material Contamination

    Lupin Pharmaceuticals is recalling Cefdinir Oral Suspension USP 250 mg/5 mL (Lot F305442, expiration 8/30/2025) due to foreign material found in reconstituted bottles. Approximately 17,070 bottles were distributed nationwide.

    Product
    CEFDINIR — CEFDINIR (CEFDINIR)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1823-2024·2024-05-22

    Airvo 2 and myAirvo 2 Humidifiers: Alarm Speaker Defect Recall

    Fisher & Paykel's Airvo 2 and myAirvo 2 respiratory humidifiers have a speaker defect that may silence or distort critical alarm sounds. If the alarm fails and therapy is interrupted, patients could experience oxygen desaturation.

    Product
    Airvo 2 Humidifier, REF: PT101US, and myAirvo 2 Humidifier, REF: PT100US
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1829-2024·2024-05-22

    MRI System Software May Fail to Warn of Inadequate Ventilation

    Philips Ingenia 1.5T MRI systems with software R5.7.1 may not provide adequate warning for low ventilation conditions, potentially causing increased patient body temperature or burning sensation.

    Product
    Ingenia 1.5T with Evolution Upgrade 1.5T - Magnetic Resonance (MR) systems are Medical Electrical Systems indicated for use as a diagnostic device REF: 782116
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1828-2024·2024-05-22

    CoFlex NL Sterile Bandages Recalled for Packaging Seal Gaps

    Andover Healthcare Inc. is recalling CoFlex NL sterile flexible cohesive bandages (model 5400S) due to packaging seal gaps that could compromise product sterility. No illnesses have been reported.

    Product
    Sterile CoFlex NL: Latex Free Flexible Cohesive Bandage, Tan, 4INx5YD (5400S)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1789-2024·2024-05-22

    Ossur RHEO Knee XC Prosthetic Components Recall Due to Firmware Issues

    Ossur is recalling 107 RHEO Knee XC prosthetic components due to firmware issues that may cause unintended device shutdown or warnings, risking patient falls.

    Product
    RKNXC0003, RHEO KNEE XC 3 YR WARRANTY, MD, CE, External lower limb prosthetic component
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1790-2024·2024-05-22

    Prosthetic Knee Firmware Defect Risks Unintended Shutdown and Patient Falls

    The RKNXC0005 RHEO KNEE XC prosthetic knee may experience firmware issues causing unintended warnings and device shutdown, creating a fall risk for patients.

    Product
    RKNXC0005, RHEO KNEE XC 5 YR WARRANTY, MD, CE, External lower limb prosthetic component
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1797-2024·2024-05-22

    Medtronic Left Heart Vent Catheters recalled for unsealed sterile packaging

    Medtronic recalls over 13,000 Left Heart Vent Catheter units due to potential for unsealed sterile packing. Affected devices distributed worldwide.

    Product
    Medtronic Left Heart Vent Catheters: a) DLP¿ Intracardiac Sump 20 Fr, Model Number 12012, b) DLP¿ Left Heart Vent Catheter 10 Fr., Model Number 12008, c) DLP¿ Left Heart Vent Catheter 13 Fr., Model Number 12001, d) DLP¿ Left Heart Vent Catheter 13 Fr., Model Number 12113
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1808-2024·2024-05-22

    Orthopedic Growth Control Plating System Recalled for Incorrect Implant Material

    Wishbone Medical recalls the WishFIX Growth Control Plating System because some units contain Stainless-Steel implants instead of the labeled Titanium implants. The recall affects 60 units distributed in Florida, New Jersey, and Connecticut.

    Product
    WishFIX Growth Control Plating System, Model Number: TEFCS28-080US. Orthopedic device.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1793-2024·2024-05-22

    Medtronic Arterial Cannulae Recalled Due to Unsealed Sterile Packaging

    Medtronic Perfusion Systems is recalling multiple arterial cannula models worldwide due to potential for unsealed sterile packing. Compromised packaging may allow contamination of devices intended for clinical use.

    Product
    Medtronic Arterial Cannulae packaged as: a) DLP¿ Curved Metal Tip Arterial Cannula 20 Fr., Model Number 80020; b) DLP¿ Curved Metal Tip Arterial Cannula 20 Fr., Model Number 80220; c) DLP¿ Curved Metal Tip Arterial Cannula 20 Fr., Model Number 82020; d) DLP¿ Curved Metal
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1796-2024·2024-05-22

    Medtronic Arteriotomy Cannula Recall Due to Potential Unsealed Sterile Packing

    Medtronic is recalling 7,935 units of I.M.A. Arteriotomy Cannula Model 31001 worldwide due to potential for unsealed sterile packing. Affected healthcare providers should verify lot numbers against inventory.

    Product
    Medtronic I.M.A. Cannulae: DLP¿ 1 mm Arteriotomy Cannula, Model Number 31001
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1831-2024·2024-05-22

    CARDIOHELP-i System Recalled for Elevated Patient Leakage Current

    Maquet Medical Systems USA is recalling the CARDIOHELP-i System because measured patient leakage current in some units significantly exceeded expected safety levels.

    Product
    CARDIOHELP-i System. Blood oxygenation and carbon dioxide removal system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1821-2024·2024-05-22

    APTUS 2.8 TriLock Bone Fixation Screws Recalled for Incorrect Length

    Medartis Inc. is recalling APTUS 2.8 TriLock Screws (lot 24377397) because some units are 16mm long instead of the specified 22mm, which could compromise bone fixation stability.

    Product
    APTUS 2.8 TriLock Screw 22mm, HD7, 1/Pkg. Metal bone fixation fastener used with the APTUS fixation system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1822-2024·2024-05-22

    Novalung Sensor Box Recalled for Flow Measurement Technical Failure

    Fresenius is recalling 88 Novalung sensor boxes for error messages affecting flow measurement. The defect impacts measurement capabilities in a life-support system used for acute respiratory and cardiac failure patients.

    Product
    Novalung sensor box is a component of the Novalung Console (F30000162)-Indicated for long-term (> 6 hours) respiratory/ cardiopulmonary support that provides assisted extracorporeal circulation and physiologic gas exchange (oxygenation and CO2 removal) of the patient's blood in a
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1820-2024·2024-05-22

    HeartSine Public Access Defibrillators Recalled for Voice Prompt Manufacturing Defect

    Certain HeartSine PAD defibrillators may fail to deliver voice prompts during emergency use due to a manufacturing defect, potentially delaying therapy. Visual instructions remain available.

    Product
    HeartSine samaritan PAD (Public Access Defibrillator), Type: SAM 350P, SAM 360P, SAM 450P
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1800-2024·2024-05-22

    Medtronic Aortic Root Cannulae and Cardioplegia Needles Recalled for Unsealed Sterile Packing

    Medtronic is recalling aortic root cannulae and cardioplegia needles used in cardiac surgery due to potential unsealed sterile packaging. Approximately 2,622 units were distributed worldwide.

    Product
    Medtronic Aortic Root Cannulae and Cardioplegia Needles: a) DLP¿ 9 Ga (11 Fr) Aortic Root Cannula, Model Number 24009; b) DLP¿ 16 Ga (5 Fr) Cardioplegia Needle Neonatal 0.64 cm (1/4 in) Tip Length, Model Number 11316; c) M+AR" 14 Ga (7 Fr) Aortic Root Cannula with Flow-
    Category
    Medical Device
    Distribution
    0 states