The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

15076–15100 of 31509

  • HighFDA (Devices)·Z-1066-2024·2024-02-21

    Bone Filler Tubes Recalled Due to Manufacturing Process Defect

    The FDA is recalling 89 AFT Bone Filler Tubes due to a manufacturing process defect that could cause extrudability issues during surgery. The filling process did not demonstrate adequate capability.

    Product
    AFT (Allograft Filler Tube) Straight Tube (1/2 Filled), Product Code 227010 (bone void filler)
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1072-2024·2024-02-21

    Philips ProxiDiagnost N90 X-ray System Recall for Patient Data and Security Issues

    Philips is recalling 138 U.S. units of its ProxiDiagnost N90 radiography system due to two identified issues. The system may display incorrect patient images during scan transitions, and a security vulnerability could allow unauthorized data access with physical device access.

    Product
    ProxiDiagnost N90- A Multi-functional general Radiography and Fluoroscopy (R/F) system Ref: (1)706100 (2)706110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1073-2024·2024-02-21

    Philips Recalls ProxiDiagnost Radiography Systems for Patient Data Display and Security Issues

    Philips is recalling 20 ProxiDiagnost radiography/fluoroscopy systems due to two issues: potential display of previous patient images when scanning new patients, and a security vulnerability allowing unauthorized data access. No injuries have been reported.

    Product
    ProxiDiagnost upgrade- A Multi-functional general Radiography and Fluoroscopy (R/F) system Ref:706150
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1087-2024·2024-02-21

    Philips CombiDiagnost R90 Fluoroscopy Device May Display Wrong Patient Images

    The Philips CombiDiagnost R90 fluoroscopy device may display a previous patient's radiography images during an examination, risking privacy violation and diagnostic errors in 86 affected units.

    Product
    CombiDiagnost R90 1.0 (709030)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1067-2024·2024-02-21

    Bone void filler recalled due to manufacturing process control issue

    Musculoskeletal Transplant Foundation recalled 50 units of AFT Allograft Filler Tubes in Minnesota due to an unqualified manufacturing filling process. The product may have extrudability issues causing extended surgery time.

    Product
    AFT (Allograft Filler Tube) Diverted Tube (3/4 Filled), Product Code 227005 (bone void filler)
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1141-2024·2024-02-21

    HeartSine Samaritan PAD Defibrillators Recalled for Test Configuration Flaw

    HeartSine samaritan PAD defibrillators shipped in test configuration may have incorrect CPR timing and delayed or no therapy delivery in cardiac events. Users should stop using affected units and contact the manufacturer.

    Product
    HeartSine samaritan PAD (Public Access Defibrillator): Type/Catalog: SAM 350P/350-UNIT-US-10, 350-STR-US-10, 350-STR-UK-10; SAM 360P/360-STR-JA-10, 360-STR-DE-10, 360-STR-UK-10; SAM 450P/450-UNIT-US-08, ; SAM 500P/500-BAS-UK-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1077-2024·2024-02-21

    Medical Device Recall: Heart-Lung Machine Component Sterile Barrier Defect

    The BEQ-HLS 7050 USA HLS Set Advanced 7.0 is recalled due to a compromised sterile barrier on its Emergency Priming Line component. This defect may cause inflammation, sepsis, or infection.

    Product
    BEQ-HLS 7050 USA, HLS Set Advanced 7.0, Product Code/Part Number 70106.9078. Used with the CARDIOHELP heart-lung machine.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1056-2024·2024-02-21

    Samsung GM85 Mobile X-ray System Welding Frame Defect Arm Fall Risk

    NeuroLogica is recalling 261 Samsung GM85 mobile x-ray systems due to a welding defect in the moving arm frame that could cause the arm to fall, risking bodily injury.

    Product
    Samsung Digital Diagnostic Mobile X-ray System, Model GM85.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1078-2024·2024-02-21

    Skin Graft Carrier Recalled for Manufacturing Ratio Defect

    Zimmer Surgical Inc. is recalling 3:1 Dermacarrier skin graft carriers due to a manufacturing defect where the ridge pattern is 1.5:1 instead of 3:1, potentially causing tissue damage or additional grafting.

    Product
    3:1 Dermacarrier, Model Number 00219501300, skin graft carrier
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0325-2024·2024-02-21

    Vasopressin Compounded Injectable Syringes Recalled for Sub-Potency Failure

    IntegraDose Compounding Services is recalling Vasopressin injectable syringes because the medication may lose potency before its labeled expiration date, potentially leaving patients with reduced doses.

    Product
    Vasopressin 2 Units/2 mL in 0.9% Sodium Chloride Sterile Syringe for Injection, Concentration: 1 Unit/mL, 2 mL Syringe, Rx Only, 719 Kasota Ave SE, Minneapolis, MN, Compounded Drug Not for Resale. Office Use Only, NDC 71139-0190-1.
    Category
    Drug
    Distribution
    1 state
  • HighFDA (Devices)·Z-1089-2024·2024-02-21

    global Medium embryo culture media recalled for potential development impairment

    CooperSurgical is recalling three specific lots of global Medium embryo culture media distributed to fertility clinics worldwide due to performance issues that may impair embryo development during culture.

    Product
    global Medium, Model Numbers LGGG-020 (20mL bottle), LGGG-050 (50mL bottle), LGGG-100 (100mL bottle). Intended use: Culture of human embryos from zygote to blastocyst, embryo transfer.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0872-2024·2024-02-21

    Woodstock 5 Grain Cereal recalled for undisclosed wheat allergen

    Woodstock 5 Grain Cereal is recalled because triticale, a product ingredient, is not identified as wheat on the label. This creates a risk for people with wheat allergies.

    Product
    Woodstock 5 Grain Cereal. Oats, Rye, Triticale, Barley, Golden Flax. Net Wt. 18.5 oz (1 lb 2.5 oz) 524g. UPC 0 42563-01772 9. Distributed by Woodstock, 313 Iron Horse Way, Providence, RI 02908. Packaged in a plant that also processes wheat.
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1085-2024·2024-02-21

    Stryker Trevo Trak 21 Microcatheter Recalled for Unevaluated Intended Use

    Stryker, Inc. is recalling 63 units of the Trevo Trak 21 Microcatheter because the device instructions contain an intended use that has not been evaluated by the FDA.

    Product
    Stryker Neurovascular, Trevo Trak 21 Microcatheter, REF 90338, 0.021in X162cm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1068-2024·2024-02-21

    OriGen Biomedical Accessory Syringe Sets Recalled for Sterilization Incompatibility

    OriGen Biomedical is recalling 3,613 cases of accessory syringe sets due to design and material changes that caused loss of gamma sterilization compatibility, resulting in yellowed discoloration and unqualified product status.

    Product
    Accessory Sets Syringes: 6ml syringe with a female luer with 15cm sealed SCD tubing, REF: RF-T15, and 60ml syringe on a female luer with 15cm sealed SCD tubing, REF: 15-RF60-T
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-1083-2024·2024-02-21

    Portable X-ray system may move unexpectedly if improperly cleaned

    The MobileDiagnost wDR portable X-ray system may move unexpectedly if excessive liquid is used during cleaning. This affects 851 devices distributed nationwide.

    Product
    MobileDiagnost wDR, Model numbers 712001, 712002, 712004, 712006, and 712007
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0871-2024·2024-02-21

    Dannon Plain Yogurt 32oz cartons recalled for potential sanitizer contamination

    DANONE US LLC is recalling Dannon Plain Yogurt 32oz cartons distributed in Georgia due to potential contamination with sanitizer. The affected product expires 03/13/24.

    Product
    Dannon Plain Yogurt packaged in 32oz plastic carton with lid - 6 cartons per case
    Category
    Food
    Distribution
    0 states
  • HighFDA (Devices)·Z-1140-2024·2024-02-21

    FilmArray GI diagnostic kits recalled due to false positive Norovirus results

    BioFire Diagnostics is recalling FilmArray GI diagnostic test kits due to potential signals of increased false positive Norovirus results. Approximately 64,594 kits representing 2.3 million tests have been distributed worldwide.

    Product
    FilmArray Gastrointestinal (GI) Panel RFIT-ASY-0116 (30 test kit) RFIT-ASY-0104 (6 test kit) Gastrointestinal microorganism multiplex nucleic acid-based assay. In vitro diagnostic.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1139-2024·2024-02-21

    BIOFIRE BCID2 Blood Culture Panel Recalled for False Positive Candida tropicalis Results

    BioFire Diagnostics recalls BIOFIRE BCID2 panels due to false positive Candida tropicalis detection when used with certain BD BACTEC culture vials. The vials contain non-viable organism DNA that triggers incorrect positive results.

    Product
    BIOFIRE Blood Culture Identification 2 (BCID2) Panel when used with: BD BACTEC Lytic Anaerobic medium BD BACTEC Peds Plus medium BD BACTEC Plus Aerobic medium BD BACTEC Plus Anaerobic medium BD BACTEC Standard Aerobic medium BD BACTEC Standard Anaerobic medium The BIO
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1088-2024·2024-02-21

    Philips CombiDiagnost R90 Fluoroscopy Display May Show Previous Patient Images

    Philips CombiDiagnost R90 fluoroscopy systems may display a previous patient's images during radiography examination, potentially showing different image content, format, and size that could affect imaging accuracy.

    Product
    CombiDiagnost R90 1.1 (709031)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1084-2024·2024-02-21

    Stryker Neurovascular Trevo Pro Microcatheter Recalled for Unevaluated Use Statement

    Stryker is recalling the Trevo Pro 18 Microcatheter because its instruction manual contains an intended use that the FDA has not evaluated. The recall affects 11 units distributed across the United States.

    Product
    Stryker Neurovascular, Trevo Pro 18 Microcatheter, REF 90238 0.021in X150cm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1086-2024·2024-02-21

    Quidel Sofia 2 Flu + SARS Test Kits Recalled for Incorrect Expiration Dates

    Quidel Corporation is recalling one lot of Sofia 2 Flu + SARS Antigen FIA diagnostic test kits due to incorrect expiration dates on packaging. Kits labeled to expire April 30 and May 31, 2025 actually expire September 12, 2024.

    Product
    The Sofia 2 Flu + SARS Antigen FIA employs immunofluorescence technology in a sandwich design that is used with Sofia 2 to detect nucleocapsid protein from influenza A, influenza B, and SARS-CoV-2. This test allows for the detection of SARS-CoV and SARS-CoV-2, but does not differ
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0324-2024·2024-02-21

    HydrALAZINE Hydrochloride Tablets Recalled for Out-of-Specification Impurities

    HydrALAZINE Hydrochloride Tablets Lot T04680 are recalled for out-of-specification impurities found during routine testing. No illnesses have been reported, but the product poses a remote risk of reversible effects.

    Product
    HydrALAZINE Hydrochloride Tablets, USP 10mg, packaged in 100-count (10x10 blister cards), Lot T04680, Rx only, Manufactured for Heritage Pharmaceuticals, Inc. Eatontown, NJ, Distributed by Major Pharmaceuticals Livonia MI. NDC 0904-6440-61
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0322-2024·2024-02-21

    Nortrel 7/7/7 Oral Contraceptive Recalled for Discolored Tablets

    Teva Pharmaceuticals is recalling Nortrel 7/7/7 oral contraceptive tablets due to a manufacturing defect: discolored blue tablets mixed with white inert tablets. This could cause confusion about which tablets to take in the triphasic regimen.

    Product
    NORTREL 7/7/7 — NORTREL 7/7/7 (NORETHINDRONE AND ETHINYL ESTRADIOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-0873-2024·2024-02-21

    Gluten Free Bean and Cheese Burrito recalled for plastic contamination

    Amy's Kitchen is recalling Gluten Free Bean and Cheese Burritos (5.5 oz) due to the possible presence of plastic material in the product. The recall affects lot #30K0823 with best before date November 2025.

    Product
    Gluten Free Bean and Cheese Burrito (5.5 oz), individual plastic overwrap, 12 retail units/case, frozen
    Category
    Food
    Distribution
    13 states
  • LowFDA (Drugs)·D-0321-2024·2024-02-21

    Nortrel Oral Contraceptive Tablets Recalled for Discolored Inert Remainder Tablets

    Teva Pharmaceuticals is recalling 12,916 cartons of Nortrel oral contraceptive tablets nationwide due to discolored inert remainder tablets that may cause confusion. Affected lot: #100042978, expiration 7/31/2024.

    Product
    NORTREL — NORTREL (NORETHINDRONE AND ETHINYL ESTRADIOL)
    Category
    Drug
    Distribution
    Distributed nationwide