The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

21151–21175 of 27451

  • HighFDA (Devices)·Z-1773-2022·2022-09-28

    Ethicon PDS II Surgical Sutures Recalled for Incorrect Material

    Ethicon recalls PDS II surgical sutures distributed in Japan due to potential incorrect material composition that could affect treatment outcomes. No injuries have been reported.

    Product
    PDS II (polydioxanone) Suture, Product Code Z771D 4-0 PDS Suture, Violet, 8x18" (45cm), SH-1 Control Release Needles
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1765-2022·2022-09-28

    Medical device set recalled for potential sterility barrier compromise

    Maquet Medical Systems USA is recalling the BEQ-HLS 5050 (HLS Set Advanced 5.0) due to a potential breach in the sterility barrier that may compromise product sterility.

    Product
    BEQ-HLS 5050 USA; HLS Set Advanced 5.0 Part No. 70105.2797. A preconnected set used for extracorporeal respiratory and/or cardiovascular support, as part of the CARDIOHELP System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1740-2022·2022-09-28

    That's It. Dark Chocolate Banana Truffles Recalled for Undeclared Milk

    That's It. Dark Chocolate Banana Truffles are being recalled because they contain undeclared milk (casein and whey). People with milk allergies should not consume these products.

    Product
    That's It. Dark Chocolate Banana Truffles Net WT. 3.5 oz, 5.0 oz, and 16.0 oz Ingredients: Organic Bananas, Organic Dark Chocolate (Organic Unsweetened Chocolate, Organic Sugar, Organic Cocoa Butter) Prepared by: That's It Nutrition LLC Los Angeles, CA 90014 CA.THATSITFRUIT>COM 8
    Category
    Food
    Distribution
    8 states
  • HighFDA (Devices)·Z-1769-2022·2022-09-28

    Hemodialysis Water Purification Unit Recalled for Missing EMI Shielding

    Fresenius is recalling 24 units of the AquaC UNO H reverse osmosis unit because internal ethernet cables lack ferrite cores, compromising electromagnetic compatibility in hemodialysis water purification systems.

    Product
    AquaC UNO H [120V, 60Hz, 1000VA, US-Version - a reverse osmosis unit intended for use with hemodialysis systems. Fresenius Part Number: 24-10VA-1 Vivonic Part Number: G02000970-US
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1773-2022·2022-09-28

    Veggie Blend with Dip recalled due to inadequate wash water sanitizer

    Russ Davis Wholesale is recalling Veggie Blend with Dip products due to inadequate sanitizer in wash water. The recall affects products in six Midwestern states.

    Product
    Veggie Blend with Dip. Contains: Carrots, Cauliflower, Broccoli, Dill Dip. Keep Refrigerated. Net Wt. 12 oz. Item 82714. Packaged in the following brands Crazy Fresh, quick & easy, and grocery store brands.
    Category
    Food
    Distribution
    6 states
  • HighFDA (Food)·F-1776-2022·2022-09-28

    Blueberry Salsa Recalled Due to Inadequate Wash Water Sanitation

    Russ Davis Wholesale is recalling Blueberry Salsa due to inadequate sanitizer in wash water. The product was distributed to retailers in Iowa, Michigan, Minnesota, North Dakota, South Dakota, and Wisconsin.

    Product
    Blueberry Salsa. Contains: Mango, Blueberries, Red Bell Pepper, Pineapple, Green Bell Pepper, Papaya, Jalapeno Pepper, Onion, Orange, Cilantro, Lime Juice. Keep Refrigerated. Packaged in the following brands and sizes: 1. Item 85094. Net Wt. 8 oz. Crazy Fresh, qu
    Category
    Food
    Distribution
    6 states
  • HighFDA (Food)·F-1764-2022·2022-09-28

    Kiwi and strawberry products recalled due to inadequate sanitizer

    Russ Davis Wholesale is recalling kiwi and strawberry products distributed across six Midwest states due to inadequate sanitizer in wash water, creating risk of pathogenic contamination. No illnesses have been reported.

    Product
    Kiwi, Strawberry. Keep Refrigerated. Packaged in the following brands and sizes: 1. Item 80850. Net Wt. 12 oz. Crazy Fresh, quick & easy, and grocery store branded. 2. Item 80871. Net Wt 20 oz. Crazy Fresh, quick & easy, and grocery store branded.
    Category
    Food
    Distribution
    6 states
  • HighFDA (Food)·F-1758-2022·2022-09-28

    Vegetables recalled due to inadequate wash water sanitizer

    Russ Davis Wholesale is recalling vegetables and fruits sold under multiple brands in six Midwestern states due to inadequate sanitizer in the wash water. No illnesses have been reported.

    Product
    Tomato, Radish, Broccoli, Cauliflower. Net Wt. 11 oz. Item 80819 Packaged under the following brands: Crazy Fresh, quick & easy, and grocery store branded.
    Category
    Food
    Distribution
    6 states
  • HighFDA (Devices)·Z-1753-2022·2022-09-28

    BD MaxGuard Extension Set Mislabeled With Wrong Expiration Date

    BD MaxGuard Extension Set units have labels listing 2027 as the expiration year instead of 2025. Using expired medical devices may compromise product integrity and increase the risk of leaks and infection.

    Product
    BD MaxGuard Extension Set, REF: ME1069
    Category
    Medical Device
    Distribution
    39 states
  • HighFDA (Food)·F-1756-2022·2022-09-28

    Strawberry Parfait recalled due to inadequate wash water sanitizer

    Russ Davis Wholesale is recalling Strawberry Parfait products due to inadequate sanitizer in wash water. The affected products were sold under Crazy Fresh and Kowalski's Markets brands and distributed in Iowa, Michigan, Minnesota, North Dakota, South Dakota, and Wisconsin.

    Product
    Strawberry Parfait, Net Wt. 6 oz (170 g) Keep Refrigerated. Packaged under the following brands: 1. Item 80730 Crazy Fresh, or quick & easy. UPC 95631-80730 2. Item 80735 Kowalski's Markets. UPC 95631-80735
    Category
    Food
    Distribution
    6 states
  • HighFDA (Food)·F-1743-2022·2022-09-28

    Dark Chocolate Date Truffles Recalled for Undeclared Milk Allergen

    That's It. Dark Chocolate Date Truffles are recalled for containing undeclared milk (casein and whey). Consumers with milk allergies should not consume these products.

    Product
    That's It. Dark Chocolate Date Truffles Net WT. 3.5 oz, 5.0 oz, and 16.0 oz Ingredients: Organic Dates, Organic Dark Chocolate (Organic Unsweetened Chocolate, Organic Sugar, Organic Cocoa Butter). Prepared by: That's It Nutrition LLC Los Angeles, CA 90014 CA.THATSITFRUIT>COM 888-
    Category
    Food
    Distribution
    8 states
  • HighFDA (Devices)·Z-1764-2022·2022-09-28

    FDA expands recall: HLS Set Advanced 7.0 sterility barrier compromise

    Maquet Medical Systems USA has expanded a recall for HLS Set Advanced 7.0, a preconnected medical device used for heart and lung support, due to a potential breach in the sterility barrier that could compromise product sterility.

    Product
    BEQ-HLS 7050 USA; HLS Set Advanced 7.0 Part No. 70105.2794. A preconnected set used for extracorporeal respiratory and/or cardiovascular support, as part of the CARDIOHELP System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1758-2022·2022-09-28

    BD MaxGuard Extension Set Wrong Expiration Label Poses Infection Risk

    CAREFUSION is recalling 600 BD MaxGuard Extension Sets because labels list expiration year 2027 instead of 2025. Using expired products may cause leaks and infection risk.

    Product
    BD MaxGuard Extension Set with 0.2 Micron Filter and Needleless Y-Site, REF: MX9166
    Category
    Medical Device
    Distribution
    39 states
  • HighFDA (Food)·F-1784-2022·2022-09-28

    Russ Davis Wholesale Dragon Fruit Mix Recalled for Inadequate Sanitization

    Russ Davis Wholesale is recalling Dragon Fruit Mix due to inadequate sanitizer in wash water during production. The recall affects specific lot codes distributed in six Midwest states.

    Product
    Dragon Fruit Mix. Contains: Mango, Dragon Fruit, Pineapple, Clementines, Blueberries. Keep Refrigerated. Item 89348. Net Wt. 16 oz. Kowalski's Markets.
    Category
    Food
    Distribution
    6 states
  • HighFDA (Food)·F-1766-2022·2022-09-28

    Fruit Tray Recalled for Inadequate Sanitizer in Wash Water

    Russ Davis Wholesale, LLC is recalling fruit trays containing honeydew, pineapple, cantaloupe, red grapes, and strawberry due to inadequate sanitizer in wash water. The recall affects 87,915 units distributed across six Midwestern states.

    Product
    Fruit Tray. Contains Honeydew, Pineapple, Cantaloupe, Red Grapes, Strawberry. Keep Refrigerated. Item 80902. Net Wt. 4 lb. Packed under brands: Crazy Fresh, quick & easy, and grocery store branded.
    Category
    Food
    Distribution
    6 states
  • HighFDA (Devices)·Z-1756-2022·2022-09-28

    BD MaxGuard Administration Set Recalled for Incorrect Expiration Date Labels

    BD MaxGuard Drop Administration set labels incorrectly list expiration year 2027 instead of 2025. Use of expired product risks compromised integrity, potential leaks, and patient or worker infection.

    Product
    BD MaxGuard Drop Administration set with 3 Needleless Y-Sites Removable 3-port Manifold and removable 4-way stopcock, REF: MX4436
    Category
    Medical Device
    Distribution
    39 states
  • HighFDA (Food)·F-1744-2022·2022-09-28

    That's It Dark Chocolate Fig Truffles Recalled for Undeclared Milk

    That's It. Dark Chocolate Fig with Sea Salt Truffles contain undeclared milk (casein and whey) not listed in ingredients. The product poses a risk to consumers with milk allergies.

    Product
    That's It. Dark Chocolate Fig with Sea Salt Truffles Net WT. 3.5 oz, 5.0 oz, and 16.0 oz Ingredients: Organic Figs, Organic Dark Chocolate (Organic Unsweetened Chocolate, Organic Sugar, Organic Cocoa Butter), sea salt Prepared by: That's It Nutrition LLC Los Angeles, CA 90014 CA
    Category
    Food
    Distribution
    8 states
  • HighFDA (Devices)·Z-1760-2022·2022-09-28

    BD MaxGuard Administration Set Recalled for Incorrect Expiration Labeling

    CAREFUSION is recalling BD MaxGuard 15 Drop Administration Sets with incorrect expiration year labels (showing 2027 instead of 2025). Use of expired product may compromise integrity and risk infection.

    Product
    BD MaxGuard 15 Drop Administration Set with 4 Needleless Y-Sites, REF: MX9433
    Category
    Medical Device
    Distribution
    39 states
  • HighNHTSA·22V718000·2022-09-26

    2023 Volkswagen Atlas Models Recalled for Brake Line Leaks

    Volkswagen is recalling 2023 Atlas and Atlas Cross Sport models due to brake lines that may leak at threaded connections. A brake fluid leak can increase stopping distance, raising crash risk.

    Product
    VOLKSWAGEN — 2023 VOLKSWAGEN ATLAS CROSS SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·22227·2022-09-22

    Spalding Momentous EZ Portable Basketball Goals Recalled for Impact Injury Risk

    Russell Brands is recalling about 13,400 Spalding Momentous EZ Portable Basketball Goals because welds in the arm attaching the backboard to the pole can fail, causing the backboard to fall and strike users. The firm has received 26 reports of weld failures and 2 injury reports.

    Product
    Spalding Momentous EZ Portable Basketball Goals
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·22V712000·2022-09-22

    2022 Subaru Outback Windshield Defect May Cause Detachment in Crash

    Subaru is recalling 42 2022 Outback and Impreza vehicles due to incorrect paint clearcoat that may insufficiently bond the windshield. The windshield could detach during a crash, increasing injury risk.

    Product
    SUBARU — 2022 SUBARU OUTBACK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22773·2022-09-22

    Pool and Spa Drain Covers Recalled for Entrapment Hazard

    Chyir Myd pool and spa drain covers do not meet federal entrapment-protection standards and pose a hazard to swimmers. About 300 units were sold on Amazon from September 2021 through June 2022.

    Product
    Pool and spa drain covers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·22774·2022-09-22

    Wadoy pool and spa drain covers recalled for entrapment hazard

    Find4Fix has recalled about 5,500 Wadoy eight-inch pool and spa drain covers sold on Amazon from August 2019 through June 2022 because they do not meet Virginia Graeme Baker Pool and Spa Safety Act entrapment protection standards.

    Product
    Pool and spa drain covers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·22V709000·2022-09-22

    2020-2021 GMC Acadia rearview camera may fail due to improper connector crimping

    General Motors is recalling certain 2020-2021 GMC Acadia vehicles with defective rearview camera coaxial cables that may fail or malfunction. The improperly crimped connectors can reduce rear visibility and increase crash risk.

    Product
    GMC — 2020 GMC ACADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22775·2022-09-22

    Pool and Spa Drain Covers Recalled for Entrapment Hazard

    Goetas pool and spa drain covers do not meet the Virginia Graeme Baker Pool and Spa Safety Act standards, creating an entrapment hazard for swimmers and bathers. About 300 units were sold on Amazon from October 2021 through April 2022.

    Product
    Pool and spa drain covers
    Category
    Consumer Product
    Distribution
    Distributed nationwide