The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6451–6475 of 13512

  • HighFDA (Devices)·Z-1731-2024·2024-05-08

    Medtronic Invos Infant Sensor Cables recalled for manufacturing defects

    Covidien is recalling 1,122 Medtronic Invos Reusable Infant Sensor Adapter Cables due to manufacturing defects in connectors. The defects may cause error codes or non-functioning monitoring channels.

    Product
    Medtronic Invos, Reusable Infant Sensor Adapter Cable for PM7100, REF: PMAC71RIC
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-1726-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plates May Have Improper Screw Locking

    A thread form defect in the locking holes of Zimmer surgical bone plates may prevent locking screws from securing properly, potentially causing loss of fixation during surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 4 Holes, 80 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1745-2024·2024-05-08

    Radiation therapy planning system dose calculation error

    RayStation versions 9.1.0.933 and 9.2.0.483 may incorrectly calculate dose parameters. 11 units of this radiation therapy treatment planning software were distributed worldwide.

    Product
    RayStation 9.1.0.933 and 9.2.0.483. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1729-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate Recall Due to Locking Thread Defect

    Zimmer recalls certain ZPLP Distal Lateral Fibular Plates due to thread form defects in locking holes that may prevent proper screw fixation. Affected devices may lose fixation, potentially delaying surgery or requiring additional intervention.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 10 Holes, 158 MM, Nonsterile-Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1702-2024·2024-05-08

    Abbott Cholestech LDX Battery Kit Recall: Potential Swelling Risk

    Abbott is recalling the Cholestech LDX Battery Kit due to a potential for battery swelling that could cause minor burns, cuts, abrasions, or electrical shock to users.

    Product
    Abbott Cholestech LDX Battery Kit, Model: 3LP656194-PCM-LD, PN: 55170
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1728-2024·2024-05-08

    Zimmer Fibular Plate Recall: Locking Hole Thread Form Defect

    Zimmer is recalling certain ZPLP Distal Lateral Fibular Plates due to a thread form issue in the locking holes. Improperly mating screws may not correctly lock, potentially resulting in loss of fixation and need for additional surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 8 Holes, 132 MM, Nonsterile-Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1714-2024·2024-05-08

    Zimmer Locking Plate System recalled due to thread mating defect

    Zimmer is recalling the ZPLP Distal Lateral Fibular Plate due to a thread form defect in the locking holes. Locking screws may not properly mate with the plate, potentially causing surgical delay or loss of fixation.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 16 Holes, 236 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-16
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1707-2024·2024-05-08

    Zirconium Oxide Dental Restoration Blocks Recalled for Potential Cracking

    IVOCLAR VIVADENT is recalling IPS e.max ZirCAD zirconium oxide dental blocks nationwide due to defective units that may crack during sintering and cause dental restoration fracture.

    Product
    IPS e.max ZirCAD CER/in. Prime B1 C17/5 -A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth. Article Number: 758441
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1738-2024·2024-05-08

    Jackson-Pratt Drainage Kits Shipped Unsterilized in Voluntary Removal

    Cardinal Health is voluntarily removing Jackson-Pratt drainage kits (Lot 210751D6) that were shipped without sterilization. The unsterilized devices pose an infection risk if used in patient care.

    Product
    Jackson-Pratt Universal Connector PVC Tubing Anti Reflux Transparent Y, REF SU130-4601
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1734-2024·2024-05-08

    Galaxy System Wired Controller Recalled for Unintended Scope Motion

    Noah Medical recalls 17 Galaxy System wired controllers (Model GAL-019) due to calibration misalignment that may cause unintended scope motion during bronchoscopic procedures.

    Product
    Galaxy System REF GAL-001 (specifically GAL-019, Wired Controller) The Galaxy System and its accessories are intended to provide bronchoscopic visualization of and access to patient airways for diagnostic and therapeutic procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1743-2024·2024-05-08

    RayStation radiation therapy planning software affected by source-to-surface distance calculation error

    RayStation radiation therapy treatment planning software versions 8.1.0.47, 8.1.1.8, and 8.1.2.5 may calculate source-to-surface distance incorrectly, potentially affecting dose calculations. Approximately 5 units are distributed worldwide.

    Product
    RayStation 8.1.0.47, 8.1.1.8 and 8.1.2.5. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1697-2024·2024-05-08

    Sofsilk Braided Silk sutures recalled due to excess sterilization

    One lot of Sofsilk Braided Silk sutures (Product Number S-2782K) was exposed to more sterilization cycles than approved, which may reduce tensile strength and increase risks of wound complications and infections during surgery.

    Product
    Sofsilk Braided Silk sutures, Product Number S-2782K. Nonabsorbable, sterile, non-mutagenic surgical suture composed of natural silk fibers, for use in soft tissue approximation and/or ligation.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1713-2024·2024-05-08

    Zimmer Periarticular Locking Plate screw-mating defect risks surgical fixation loss

    Zimmer's Periarticular Locking Plate System has a thread defect that may prevent proper screw locking, potentially causing loss of surgical fixation. Affected units distributed worldwide.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 12 Holes, 184 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-12
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1753-2024·2024-05-08

    Hip Cup Removal Instrument Recalled Due to Wrong Blade Assembly

    Innomed is recalling the Cup Removal Starter Instrument due to a manufacturing error where the finisher blade was affixed instead of the starter blade. The wrong blade could compromise surgical performance during hip replacement procedures.

    Product
    INNOMED CUP REMOVAL STARTER INSTRUMENT, REF 520054, Hip cutter blade cup
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-1704-2024·2024-05-08

    Zirconium oxide dental blocks recalled due to cracking risk

    IVOCLAR VIVADENT AG is recalling 7,445 units of IPS e.max ZirCAD CER/in. Prime zirconium oxide blocks because they may crack during sintering, potentially causing dental restorations to fracture in patients' mouths.

    Product
    IPS e.max ZirCAD CER/in. Prime A1 C17/5 - A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth. Article Number: 758437
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1719-2024·2024-05-08

    Zimmer Periarticular Locking Plate System Screw-Locking Defect Recall

    Zimmer is recalling Periarticular Locking Plate System Distal Lateral Fibular Plates due to threading defects that may prevent locking screws from properly mating. This could result in loss of fixation and need for additional surgery.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Left, 12 Holes, 184 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-018-12
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1748-2024·2024-05-08

    Radiation Therapy Planning System May Calculate Skin Surface Distance Incorrectly

    RayStation radiation therapy planning software versions 11.0.0.951, 11.0.1.29, 11.0.3.116, and 11.0.4.15 may calculate skin surface distance (SSD) values incorrectly, potentially affecting dose calculations. Affected software has been distributed worldwide.

    Product
    RayStation 11.0.0.951, 11.0.1.29, 11.0.3.116 & 11.0.4.15. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1716-2024·2024-05-08

    Zimmer Locking Plate System Recalls Distal Fibular Plates Due to Thread Defect

    Zimmer recalls distal fibular plates with defective locking holes that may prevent proper screw fixation during orthopedic surgery, potentially requiring additional intervention.

    Product
    ZPLP(Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Left, 6 Holes, 106 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-018-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1742-2024·2024-05-08

    Radiation therapy planning system may report overly high skin surface doses

    RayStation versions 8.0.0.61 and 8.0.1.10 are subject to a Class II FDA recall due to a potential for calculated skin surface doses to be reported as too high. Healthcare facilities using these versions should contact the manufacturer for guidance and a corrective update.

    Product
    RayStation 8.0.0.61, 8.0.1.10. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1709-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate may fail to lock screws securely

    Zimmer's Distal Lateral Fibular Plate has threading defects that may prevent screws from locking properly. The defect could go unnoticed during surgery and cause loss of fixation.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 4 Holes, 80 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1752-2024·2024-05-08

    RayStation radiation therapy system dosing parameter recall

    RayStation 15.0.0.430 radiation therapy planning system may have an elevated SSD parameter. Users should contact Raysearch Laboratories AB for corrective guidance.

    Product
    RayStation 15.0.0.430. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1715-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate may fail to lock properly

    Zimmer orthopedic plates may have thread defects preventing locking screws from properly mating, potentially resulting in loss of fixation and need for additional surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 4 Holes, 80 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 7-2357-018-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1736-2024·2024-05-08

    Unsterilized Jackson-Pratt surgical drain kits recalled by Cardinal Health

    Cardinal Health recalls Jackson-Pratt 3-Spring Reservoir Kits because specific lots were shipped before sterilization. Unsterilized surgical devices pose risk of infection.

    Product
    Jackson-Pratt 3-Spring Reservoir Kit with PVC Round Drain, 400mL, 10Fr., REF SU130-402D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1703-2024·2024-05-08

    Zirconium Oxide Dental Blocks Recalled Due to Fracture Risk

    IVOCLAR VIVADENT AG is recalling 2,286 units of zirconium oxide blocks used for dental restorations because defective units may develop cracks during processing, potentially causing restorations to fracture in patients' mouths.

    Product
    IPS e.max ZirCAD CER/in. Prime BL1 C17/3- A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth. Article Number: 758434
    Category
    Medical Device
    Distribution
    Distributed nationwide