The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

176–200 of 304

  • SevereNHTSA·22V157000·2023-03-03

    2022 Winnebago travel trailers recalled for improperly welded couplers

    Winnebago is recalling certain 2022 Micro Minnie, Minnie, and Voyage travel trailers because the coupler was improperly welded, which may cause the trailer to separate from the tow vehicle and increase crash risk.

    Product
    WINNEBAGO — 2022 WINNEBAGO MICRO MINNIE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V026000·2023-03-01

    Volkswagen Atlas and Cross Sport steering knuckle fracture recall

    Front steering knuckles in certain Volkswagen Atlas and Atlas Cross Sport vehicles may fracture, causing loss of vehicle control and increasing crash risk. Volkswagen will inspect and replace affected knuckles free of charge.

    Product
    VOLKSWAGEN — 2021 VOLKSWAGEN ATLAS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V928000·2023-02-12

    2022 Ford Bronco Airbag Sensors May Not Secure Properly

    Ford is recalling certain 2022 and 2021 Bronco vehicles because the side impact sensors may not be properly secured. This could cause airbags to deploy unintentionally or fail to deploy in a crash, increasing injury risk.

    Product
    FORD — 2022 FORD BRONCO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V663000·2023-02-08

    Coach House Platinum II recreational vehicle window adhesive failure recall

    Coach House is recalling 2019-2022 Platinum II and 2022 Platinum recreational vehicles due to window adhesive failure. The adhesive bonding the window vent may fail, potentially causing detachment and increasing crash or injury risk.

    Product
    COACH HOUSE — 2021 COACH HOUSE PLATINUM II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V396000·2023-02-05

    2022 Thor Motor Coach RV models recalled for solar panel fire risk

    Thor Motor Coach is recalling certain 2022 Sequence, Rize, Scope, and Tellaro recreational vehicles. The Flex-190 solar panel junction box may experience electrical shorts, increasing the fire risk.

    Product
    THOR MOTOR COACH — 2022 THOR MOTOR COACH SEQUENCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V259000·2023-02-04

    2022 Nissan Rogue fuel tank wall thickness defect recall

    Nissan is recalling certain 2022 Rogue vehicles due to a manufacturing defect that may cause fuel tank walls to be too thin. Road debris could puncture the tank, creating a fire hazard.

    Product
    NISSAN — 2022 NISSAN ROGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V295000·2023-02-04

    Multiple Audi vehicles recalled for defective rear axle suspension lock nuts

    Audi is recalling certain 2019-2021 vehicles for rear axle lock nuts that may break from stress corrosion. A broken lock nut can cause axle misalignment, loss of control, and increased crash risk.

    Product
    AUDI — 2020 AUDI S7
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V154000·2023-02-03

    2021–2022 Dodge Durango and Jeep Grand Cherokee Steering Recall

    Chrysler is recalling 2021–2022 Dodge Durango and 2022 Jeep Grand Cherokee vehicles due to steering gear defect. The rack bar may have been insufficiently hardened, potentially causing loss of steering control.

    Product
    DODGE — 2021 DODGE DURANGO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V921000·2023-01-12

    2021 Porsche Taycan Suspension Strut Defect May Cause Loss of Vehicle Control

    A retaining ring on the 2021 Porsche Taycan's suspension strut may come loose, causing loss of vehicle control and increasing crash risk. Repairs will be provided free by Porsche dealers.

    Product
    PORSCHE — 2021 PORSCHE TAYCAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V837000·2023-01-10

    2020-2023 IC Bus School Buses Recalled for Engine Shut Down Risk

    Navistar is recalling 2020-2023 IC Bus CESB school buses due to an engine control module defect that may cause unexpected engine shutdown while driving, increasing the risk of crashes and emergency evacuation situations.

    Product
    IC BUS — 2023 IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V503000·2023-01-07

    2022 CAN-AM Ryker Motorcycles: Handlebar Stem Bolt Breakage Recall

    CAN-AM is recalling 2022 Ryker motorcycles due to handlebar stem bolts that may break unexpectedly, causing sudden loss of steering control and crash risk.

    Product
    CAN-AM — 2022 CAN-AM RYKER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V501000·2023-01-07

    2022 Toyota Tundra rear camera software defect increases crash risk

    The 2022 Toyota Tundra with Panoramic View Monitor may display front camera footage instead of rear camera when in reverse, reducing rear visibility and increasing crash risk. Toyota will reprogram the parking assist system free of charge.

    Product
    TOYOTA — 2022 TOYOTA TUNDRA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V391000·2023-01-06

    2023 Entegra Odyssey motorhomes recalled for loose rear axle bolts

    Jayco is recalling certain 2023 Entegra Odyssey motorhomes because bolts securing the rear axle rotor to the wheel hub may be improperly tightened, potentially causing wheel separation and increased crash risk.

    Product
    ENTEGRA — 2023 ENTEGRA ODYSSEY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V481000·2023-01-06

    Truck battery cable defect recall: Western Star and Freightliner vehicles

    Daimler Trucks North America is recalling certain Freightliner and Western Star trucks because the battery cable terminal may break, causing engine stall and crash risk. Dealers will repair or replace the cables at no cost.

    Product
    WESTERN STAR — 2020 WESTERN STAR WJ121
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V210000·2023-01-03

    2021 Chevrolet Tahoe seat belt latch may be inaccessible

    GM is recalling certain 2021 Chevrolet Tahoe vehicles because the second-row center seat belt latch may be trapped beneath the trim bezel. Passengers cannot use this seat belt, increasing injury risk in a crash.

    Product
    CHEVROLET — 2021 CHEVROLET TAHOE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V214000·2023-01-03

    RV Chassis steering column defect may cause loss of steering

    Shyft Group is recalling certain 2021-2022 Spartan RV Chassis K1-K4 vehicles. A steering column defect may cause the steering output shaft to disengage, resulting in loss of steering control and crash risk.

    Product
    SPARTAN — 2021 SPARTAN K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V923000·2022-12-11

    2022 Ford Super Duty F-250 and F-350 Driver-Side Air Bag Cover Defect Recall

    Ford is recalling 2022 Super Duty F-250 and F-350 vehicles due to an insufficient driver-side air bag cover that may break apart during a crash, projecting fragments toward occupants and increasing injury risk.

    Product
    FORD — 2022 FORD F-250 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V681000·2022-12-09

    Commercial Trucks Recalled for Steering Shaft Component Failure

    Daimler Trucks North America is recalling 2022-2023 Western Star 47X and 49X commercial trucks because the steering shaft's u-joint pinch bolt may detach, causing loss of steering control.

    Product
    WESTERN STAR — 2022 WESTERN STAR 47X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V379000·2022-12-05

    2021 Ford F-350 and F-450 Cracked Fifth Wheel Mounting Bracket Recall

    Ford is recalling certain 2021 F-350 SD and F-450 SD vehicles with fifth wheel left-hand mounting brackets that may be cracked. A cracked bracket could result in the fifth wheel detaching during towing, increasing crash risk.

    Product
    FORD — 2021 FORD F-350 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V202000·2022-12-03

    2020-2021 Ford F-53 and F-59 Motorhome Rear Bearing and Axle Defect

    Ford is recalling certain 2020-2021 F-53 and F-59 motorhome and commercial chassis vehicles due to inadequate rear axle lubricant. The defect may cause rear wheel bearing damage, rear axle failure, and loss of motive power and brake function.

    Product
    FORD — 2020 FORD F-53
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V206000·2022-12-03

    Western Star 4700 and 5700 Ground Harness Wiring Defect

    DTNA is recalling 2019-2021 Western Star 4700 and 5700 vehicles with undersized ground harness wiring that may cause connector melting and engine stall, increasing crash risk. Owners should contact DTNA for free replacement.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V920000·2022-11-11

    Toyota Tundra and Sequoia Power Steering Gear Assembly Defect Recall

    Toyota is recalling 2007-2021 Tundra and 2008-2022 Sequoia vehicles due to defective power steering gear assemblies that can leak oil, causing sudden loss of power steering assist and increased crash risk.

    Product
    TOYOTA — 2007 TOYOTA TUNDRA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V742000·2022-11-09

    2022 Nissan Pathfinder: Third-Row Headrests May Detach or Move

    Nissan is recalling 2022 Pathfinder vehicles because the third-row headrests may move or detach due to improper welds or misaligned components. Detached headrests could fail to restrain occupants in a crash, increasing injury risk.

    Product
    NISSAN — 2022 NISSAN PATHFINDER
    Category
    Vehicle
    Distribution
    Distributed nationwide