The Recall Desk

Vehicle

Freightliner 114sd

29 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–29 of 29

  • SevereNHTSA·23V105000·2024-08-02

    Freightliner commercial trucks recalled for drag link separation defect

    Certain 2019-2021 Freightliner commercial trucks are being recalled because the drag link taper joint may not be sufficiently tightened, potentially causing complete separation from the steering arm and total loss of steering control.

    Product
    FREIGHTLINER — 2020 FREIGHTLINER COLUMBIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V722000·2024-04-09

    2023 Western Star 49X Trucks Recalled Due to Tie Rod Defects

    Certain 2023 Western Star and Freightliner trucks are being recalled because tie rod clamps may be improperly heat-treated and crack, potentially causing loss of steering control.

    Product
    WESTERN STAR — 2023 WESTERN STAR 49X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V509000·2024-03-07

    2025 Freightliner and Western Star Steering Tie Rod Assembly Defect

    Certain 2025 Freightliner and Western Star commercial vehicles may have improperly heat-treated tie rod assemblies that can fail, potentially causing loss of steering control and increasing crash risk.

    Product
    FREIGHTLINER — 2025 FREIGHTLINER 114SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V571000·2024-01-08

    2025 Freightliner Cascadia Front Axle Tie Rod Defect Recall

    Certain 2025 Freightliner and Western Star commercial trucks may have defective front axle tie rods that can fail and cause loss of steering control. Owners should contact DTNA at 800-745-8000 for free replacement.

    Product
    FREIGHTLINER — 2025 FREIGHTLINER CASCADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V073000·2023-10-02

    Freightliner Cascadia and Western Star trucks recalled for brake defect

    Daimler Trucks North America is recalling certain 2017-2023 Freightliner Cascadia and Western Star trucks. Corroded brake modulator valves may cause vehicles to pull to one side during braking, increasing crash risk.

    Product
    FREIGHTLINER — 2018 FREIGHTLINER CASCADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V369000·2022-07-05

    2021–2022 Heavy-Duty Trucks Recalled for Loose Tie Rod Assembly Components

    Daimler Trucks North America is recalling certain 2021–2022 heavy-duty trucks including Freightliner and Western Star models due to potentially loose tie rod clamps. Loose or detached tie rod ends could cause steering loss and increase crash risk.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V660000·2022-03-10

    Suspension snap-ring failure could cause wheel separation on Western Star 4700

    Daimler Trucks is recalling certain 2021 Western Star and Freightliner commercial trucks because the steer axle spindle nut snap-ring may be missing or improperly installed, potentially causing wheel separation and increased crash risk.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V394000·2022-03-06

    2023 Freightliner M2 Trucks Steering Shaft Defect Recall

    Daimler Trucks North America is recalling 2023 Freightliner Business Class M2 trucks due to a u-joint pinch bolt that may detach from the steering shaft, causing loss of steering control and increasing crash risk.

    Product
    FREIGHTLINER — 2023 FREIGHTLINER BUSINESS CLASS M2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V817000·2022-01-11

    Brake modulator corrosion recall on Freightliner and Western Star commercial trucks

    Daimler Trucks North America is recalling certain Freightliner Cascadia and Western Star models due to corrosion in front brake modulator valves. The defect may cause brakes to pull to one side during automated braking, increasing crash risk.

    Product
    FREIGHTLINER — 2017 FREIGHTLINER CASCADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V256000·2021-12-04

    2021-2022 Freightliner and Western Star trucks recalled for steering bolt defects

    Daimler Trucks North America is recalling 2021-2022 Freightliner and Western Star commercial trucks with defective steering bolts that may fracture and cause loss of steering control. Dealers will replace them free of charge.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V187000·2027-01-03

    2025–2026 Western Star and Freightliner trucks recalled for brake light failure

    Daimler Trucks North America is recalling certain 2025–2026 Western Star 47X and 49X and multiple Freightliner models due to a software error that may cause brake lights to fail, increasing crash risk.

    Product
    WESTERN STAR — 2025 WESTERN STAR 47X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V603000·2025-12-09

    [pending] 2024 FREIGHTLINER BUSINESS CLASS M2

    Pending LLM rewrite. Source: NHTSA 25V603000.

    Product
    FREIGHTLINER — 2024 FREIGHTLINER BUSINESS CLASS M2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V601000·2025-12-09

    [pending] 2025 WESTERN STAR 47X

    Pending LLM rewrite. Source: NHTSA 25V601000.

    Product
    WESTERN STAR — 2025 WESTERN STAR 47X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V295000·2025-07-05

    [pending] 2025 FREIGHTLINER BUSINESS CLASS M2

    Pending LLM rewrite. Source: NHTSA 25V295000.

    Product
    FREIGHTLINER — 2025 FREIGHTLINER BUSINESS CLASS M2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V760000·2025-05-11

    [pending] 2024 WESTERN STAR 49X

    Pending LLM rewrite. Source: NHTSA 25V760000.

    Product
    WESTERN STAR — 2024 WESTERN STAR 49X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V668000·2024-10-09

    Freightliner and Western Star brake lights may fail during emergency braking

    Daimler Trucks is recalling certain Freightliner and Western Star trucks because brake lights may fail to illuminate during automatic emergency braking, increasing crash risk. Dealers will update software at no cost.

    Product
    FREIGHTLINER — 2025 FREIGHTLINER EM2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V554000·2024-05-07

    2023 Western Star and Freightliner trucks recalled for engine control module defect

    Daimler Trucks North America is recalling 1,375 certain 2023 Western Star and Freightliner commercial trucks due to engine control module defects that can cause unexpected engine shutdown, increasing crash risk.

    Product
    WESTERN STAR — 2023 WESTERN STAR 49X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V402000·2024-04-06

    Steering Tie Rod Defect Recall: 2025 Freightliner, Western Star, and FCCC Trucks

    Daimler Trucks North America is recalling 2025 Freightliner, Western Star, and FCCC commercial trucks because the front axle tie rod ball joint studs may crack, causing tie rod separation and sudden loss of steering control.

    Product
    FCCC — 2025 FCCC S2C
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V238000·2023-04-04

    Tie rod fastener defect in commercial trucks risks steering failure

    Daimler Trucks is recalling commercial vehicles with a tie rod that may be missing a fastener, allowing the steer arm to detach and causing potential loss of steering control.

    Product
    FCCC — 2023 FCCC S2RV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V237000·2023-04-04

    Freightliner and FCCC trucks recalled for windshield wiper linkage failure

    Daimler Trucks North America is recalling certain 2020-2022 Freightliner and FCCC trucks due to windshield wiper linkage failure that can reduce visibility. Dealers will inspect and replace affected parts free of charge.

    Product
    FREIGHTLINER — 2020 FREIGHTLINER M2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V919000·2022-12-12

    Freightliner and Western Star trucks recalled for tire incompatibility

    Daimler Trucks is recalling certain Freightliner and Western Star commercial trucks with tires incompatible with their 8.25-inch rims. Incompatible tires can reduce performance and increase crash risk.

    Product
    FREIGHTLINER — 2023 FREIGHTLINER 114SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V896000·2022-05-11

    Freightliner and Western Star trucks recalled for unapproved tires and wheels

    Daimler Trucks North America is recalling Freightliner 108SD, 114SD, Coronado, and Western Star trucks from model years 2012-2022 due to unapproved tires and rims that do not meet federal safety standards.

    Product
    FREIGHTLINER — 2013 FREIGHTLINER 108SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V965000·2022-01-12

    Western Star and Freightliner Trucks Fuel Tubes May Crack, Fire Risk

    Fuel tubes in certain 2019–2022 Western Star, Freightliner, and FCCC trucks may crack, causing high-pressure fuel leaks that could ignite. DTNA is offering free replacement of fuel tubes and installation of vibration isolators.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V326000·2021-07-05

    Western Star 4700 and Freightliner fuel rail defect recall

    Daimler Trucks North America recalls 2018-2021 Western Star 4700 and Freightliner trucks due to fuel rail assembly defects that could leak and cause fires in certain conditions.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V634000·2021-02-10

    Commercial trucks recalled for incorrect axle weight rating labels

    Daimler Trucks North America is recalling approximately 53 units of 2020-2021 Western Star and Freightliner commercial trucks due to incorrect Gross Axle Weight Rating information on vehicle certification labels. This could lead to axle overloading and increased crash risk.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V211000·2020-10-04

    Freightliner and Western Star trucks recalled for incorrect weight rating labels

    Daimler Trucks North America is recalling 2020-2021 Freightliner and Western Star commercial trucks with incorrect weight-rating labels. Incorrectly labeled trucks could be overloaded, increasing crash risk.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V539000·2020-03-09

    Western Star and Freightliner trucks recalled for suspension hardware defect

    Daimler Trucks recalls 2020-2021 Western Star 4700 and 4900, and Freightliner 114SD and 122SD trucks due to suspension axle hardware that may be insufficiently long to engage locking nuts, creating road hazards and crash risk.

    Product
    WESTERN STAR — 2021 WESTERN STAR 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all Freightliner models